Service manual

43
6-4. LE (Lock Error) - Door opening error
1) Conditions of Occurrence
When intending to begin cycle by pressing start/ temporary stop button while door is opened
2) All LEDs are turned off and 'LE' blinks in 18:88 display.
3) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
4) Error display is cleared when turning off/ on power.
6-5. E1 - Water level detection error
1) Conditions of Occurrence
In case water level is below reset or overflow is detected in line test mode
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E1' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.
6-6. E2 - Overflow error
1) Conditions of Occurrence
In case water level in water tank is above overflow level due to continuous operation of water supply
valve
2) Water supply motor is kept on until water level falls below reset.
3) All LEDs are turned off and 'E2' blinks in 18:88 display.
4) Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
5) Error display is cleared when turning off/ on power.