Service manual

45
6-9. Motor-related Error
1) E5 (DC-Link High Voltage) Error
In case DC-link voltage to IPM increases to 450V or higher
Motor operation is stopped and 'E5' is shown in display window.
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
2) E6 (EMG) Error
In case current detected with EMG port is of 20A or higher
Motor operation is stopped and 'E6' is shown in display window.
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
3) E7 (Direction) Error
In case signal of Hall IC is different from the predicted signal according to direction of rotation
Motor operation is stopped and 'E7' is shown in display window.
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
4) E8 (Initial Operation Fail) Error
In case input signal of Hall IC is abnormal due to problems in motor connection, etc.
Motor operation is stopped and 'E8' is shown in display window.
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
6-10. Error in Temperature Sensor
1) H2 Error - Washing temperature sensor open/ short
In case washing temperature sensor is defective or not connected
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.
2) H4 Error - Washing temperature sensor overheating
In case temperature detected by washing temperature sensor is 95 or higher
Error buzzer alarm is sounded for 10 seconds per every 10 minutes.
Error display is cleared when turning off/ on power.