- Daewo Refrigerator Manual

17
It is linked with comp.
INPUT CONTROL OBJECT
CONTENTS REMARKS
1. Comp
Louver Heater
1. Buzzer sounds if any button of Inner Control is pushed.
2. Buzzer sounds 4 times 3 seconds after initial power input.
3. Buzzer sounds for 3 or 1 times in case of A/S forced defrosting and short (pull down)
operation or explanation mode.
4. If door is open, buzzer sounds after every 1 minutes for 5 minutes (Door open alarm)
INPUT CONTROL OBJECT
CONTENTS REMARKS
1. Control (Inner or F-PCB) buttons
2. Door Switch
3. Initial Power Input
Buzzer
4-5. Louver Heater Control
4-6. Buzzer or Alarm Control
1. Control refrigerator compartment lights
R-Lights turn ON/OFF by R-door switch ON/OFF
( For 10 minutes after sensing door open, the lights turn off automatically
through door close is not sensed.)
2. Control of freezer compartment lights.
F-Light turn ON/OFF by F-door switch ON/OFF
( For 10 minutes after sensing door open, the lights turn off automatically
through door close is not sensed.)
3. R-lights ON/OFF by home bar door switch ON/OFF. ( for only model with home bar )
R-lights turn ON for 10 minutes after sensing home bar door switch open.
4. Dispenser lamp control ( for only model with water/ice dispenser )
Dispenser lamp turns ON/OFF by Dispenser switch.
Dispenser lamp turns ON for 4 seconds after sensing switch close.
INPUT CONTROL OBJECT
CONTENTS REMARKS
1. Refrigerator door switch
2. Freezer door switch
3. Home bar door switch
4. Dispenser switch
Lamp
4-7. Control of Interior Lights (FRS(N)-U20DA)