Datasheet

AB DAHRÈNTRÅD, Jonslund, SE-465 80 Nossebro
Phone: +46(0)512 - 300 300, Fax: +46(0)512 - 300 400
info@dahrentrad.se, www.dahrentrad.se
DAMID PE
Round enamelled winding wire of copper, heat resistant, class 200
04.04.13/BF
Dimension
mm
Selection of types
1)
Elongation at fracture
%
IEC
4)
DT
2)
Mandrel winding test
%
IEC
4)
DT
3)
Electrical breakdown
voltage
kV
IEC
4)
DT
Properties speci c to dimension
Typical test results compared to the IEC standard values
Increase - tolerance/mm
Nominal conductor diameter/mm
Dimensions - Tolerances
Comments:
1)
IEC 60851 - 3.2 Percentage elongation at fracture of conductor.
2)
IEC 60851 - 3.3 Refers to stretch of the wire before winding over its
own diameter
.
3)
IEC 60851 - 5.3 The voltage is measured between a twisted pair of enamelled conductors.
4)
DT = Dahréntråd.
voltage
Temperature index according to IEC 60172
Temperature/°C
Thermal life/h
10
100
1000
10000
100000
200 215 230 245 260 275 290
-0,030
-0,015
0,000
0,015
0,030
0,045
0,060
0,075
0,090
0,105
0,120
0,135
0,150
0,710 0,800 0,900 1,000 1,120 1,250 1,600 2,000 2,500 3,150 4,000 5,000
Tolerances
Grade
2
Tolerances
Grade
1
Conductor
tolerances
The technical data included is up to date at the time of printing.
Dahréntråd reserve the right to make any amendments deemed necessary.
0,710 - Grad 1
28
45
0
10
2,6
8,5
0,710 - Grad 2
28
45
0
10
4,8
10,0
1,000 - Grad 1
30
45
0
10
2,7
9,5
1,000 - Grad 2
30
45
0
10
5,0
10,0
1,400 - Grad 1
32
45
0
10
2,7
10,0
1,400 - Grad 2
32
45
0
10
5,0
10,0
2,240 - Grad 2
33
45
0
10
5,0
10,0