Operation Manual

Step 2 
Select audio channel. 
Step 3 
It is to set audio detection parameters, please refer to Table 4-27 for more details. 
Parameter 
Function 
Enable Input 
Abnormal 
Select the check box, it will generate alarm when it detects audio input 
abnormity. 
Enable Intensity 
Change 
Select the check box, it will generate alarm when it detects there is audio 
intensity change and it exceeds the threshold. 
Sensitivity 
It can be judged as audio abnormity when the input volume change exceeds 
continuous environment volume; users need to adjust according to the 
actual environment test. 
Threshold 
It is to set the filtered environment volume intensity, if the environmental 
noise is too big, then the value needs to be set higher, users can adjust 
according to the actual environment test. 
Working Period 
It is to set the alarm period, it can enable alarm event only during the period 
range which has been set. 
1.  Click “Setup” and the system will pop out the interface of “Working 
Period”.  
2.  It is to set working period according to the following methods:  
  You can input time numerical value or press the left mouse button to 
drag on the setup interface to set. 
  Click the "Setup" of corresponding week, select the check box in front of 
the period on the bottom of the interface, and input time value, there are 
six periods to be set every day. 
3.  Click “Save” to complete the setup of working period. 
Anti-dither 
System only records one motion detection event during the anti-dither 
period. 
Record 
Select check box and set record channel, the corresponding channel will 
implement alarm and record automatically when alarm happens. 
Note 
  Please refer to "4.1.2.5 Set Path" for record file storage location query 
and setting. 
  The system record needs to meet following two conditions when alarm 
happens. 
  It has enabled motion detection record, please refer to "4.5.1.1 
Configure Record Schedule" for more details. 
  It has set auto record, please refer to '4.5.3 Configure Record 
Control" for more details. 
Record Delay 
System can delay the record for specified time after alarm ended. 
Relay-out 
Connect alarm output port to alarm device (such as lamplight, siren and so 
on), select check box and set alarm output device, enable alarm linkage 
output port, and the system can activate corresponding alarm output device 
when alarm occurs. 