  In the state of drawing, select "Max Size" or "Min Size", click "Clear" to delete corresponding 
filtering box. 
4.  It is to set the parameters of tripwire, please refer to Table 4-29 for more details. 
Parameter 
Note 
Working period 
It is to set the alarm period, it can enable alarm event only during the 
period range which has been set. 
1.  Click “Setup” and the system will pop out the interface of “Working 
Period”.  
2.  It is to set working period according to the following methods:  
  You can input time numerical value or press the left mouse button to 
drag on the setup interface to set. 
  Click the "Setup" of corresponding week, select the check box in front 
of the period on the bottom of the interface, and input time value, there 
are six periods to be set every day. 
3.  Click “Save” to complete the setup of working period. 
Direction 
It is set the direction of crossing fence, you can select A→B、B→A、A↔B.  
Alarm track 
Select the check box, the tracking speed dome will automatically trigger 
alarm when the target triggers intelligent rule. 
Track time 
It is the time when the tracking speed dome automatically track the object 
which triggers alarm after alarm occurs. 
Record 
Select check box and set record channel, the corresponding channel will 
implement alarm and record automatically when alarm happens. 
Note 
  Please refer to "4.1.2.5 Set Path" for record file storage location query 
and setting. 
  The system record needs to meet following two conditions when alarm 
happens. 
  It has enabled motion detection record, please refer to "4.5.1.1 
Configure Record Schedule" for more details. 
  It has set auto record, please refer to '4.5.3 Configure Record 
Control" for more details. 
Record delay 
System can delay the record for specified time after alarm ended.  
Relay out 
Connect alarm output port to alarm device (such as lamplight, siren and so 
on), select check box and set alarm output device, enable alarm linkage 
output port, and the system can activate corresponding alarm output device 
when alarm occurs. 
Alarm delay 
It means the alarm delays a period of time to stop after alarm ends. 
Send Email 
Select check box, and the system will send email to inform users when 
alarm occurs. 
Note 