Specifications

Telit GE864 and GC864
Product Description
80273ST10008A Rev. 3 - 10/02/06
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved page 11 of 72
2.2 Weight
GE864: 6 gr
GC864: 8 gr. (preliminary)
2.3 Environmental requirements
The Telit GE864 and GC864 modules are compliant with the applicable ETSI reference
documentation GSM 05.05 Release1998.
2.3.1 Temperature range
GE864-QUAD /
GE864-PY
GC864-QUAD /
GC864-PY
Temperature in normal operating conditions
–10°C ÷ +55°C
–10°C ÷ +55°C
Temperature in extreme operating conditions*
–30°C ÷ +80°C
(preliminary)
–30°C ÷ +80°C
(preliminary)
Temperature in storage conditions
–30°C ÷ +85°C
–30°C ÷ +85°C
* Temperature exceeding the range of normal operating conditions can affect the sensitivity, the performance and
the MTBF of the module.
2.3.2 Vibration Test (non functional)
10 ÷12Hz ASD = 1.92m 2 /s 3
12 ÷ 150Hz –3dB/oct
2.3.3 RoHS compliance
As a part of Telit corporate policy regarding environmental protection, the GE864 and GC864 comply
with the RoHS (Restriction of Hazardous Substances) directive of the European Union.(EU
Directive 2002/95/EG).
2.4 Operating Frequency
The operating frequencies in GSM, DCS, PCS modes are conform to the GSM specifications.
Mode Freq. TX (MHz) Freq. RX (MHz) Channels (ARFC) TX - RX offset
850
824.2÷848.8 869.2÷893.8 0 ÷ 124 45 MHz
890.0 - 914.8 935.0 - 959.8 0 – 124 45 MHz
E-GSM-900
880.2 - 889.8 925.2 - 934.8 975 - 1023 45 MHz
DCS-1800 1710.2 - 1784.8 1805.2 - 1879.8 512 – 885 95 MHz
PCS-1900 1850.2 - 1909.8 1930.2 - 1989.8 512 - 810 80 MHz