2.8 Supply voltage
The external power supply must be connected to VBATT signal (see paragraph 2.15,Interface
connectors on GM862-GPRS) and must fulfil the following requirements:
• Nominal operating voltage 3.8 V
• Operating voltage range 3.4 V - 4.2 V
2.9 Power consumption
The typical current consumption of the Telit GM862-GPRS module are:
• Power off current (typical) 26 µA;
• Stand–by current < 17 mA
rms
(< 4 mA
rms
using command AT+CFUN )
• Operating current 250 mA
rms
@ typical network conditions
• Operating current 350 mA
rms
1.9 A
peak
@ worst network conditions
2.10 Embodied Battery charger
This feature is available only on the Telit GM862-PCS.
The battery charger is suited for 3.7V Li-Ion rechargeable battery (suggested capacity 500-
1000mAH). The Charger needs only a CURRENT LIMITED power source input and charges the
battery directly through VBATT connector pins.
• Battery charger input pin CHARGE
• Battery pins VBATT, GND
• Battery charger input voltage min 5.0 V
• Battery charger input voltage typ 5.5 V
• Battery charger input voltage max 7.0 V
• Battery charger input current max 400mA
• Battery type Rechargeable Li-Ion
NOTE: If embodied battery charger is used, then a LOW ESR capacitor of at least 100µF must be
mounted in parallel to VBATT GM862-PCS pins.
NOTE: when power is supplied to the CHARGE pin, a battery must always be connected to the