• Data shown is dry coil. Wet coil pressure drop is approximately: 0.1” H
2
0, for two-row indoor coil; 0.2” H
2
O, for three-row indoor coil; and 0.3” H
2
0, for
four-row indoor coil.
• Data shown does not include filter pressure drop, approx. 0.08” H
2
0.
• Reduce airflow by 2% for 208-volt operation.
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9
CFM
580 505 445 390 320
WATTS
36 46 54 60 65
CFM
900 850 800 740 655 605 555 490 420
WATTS
92 101 110 119 126 135 140 145 153
CFM
1230 1190 1140 1095 1040 990 920 850 785
WATTS
202 212 220 233 235 243 249 262 265
CFM
- 550 475 415 340 270 - - -
WATTS
- 5059667477 - - -
CFM
1070 1030 985 935 875 770 705 660 -
WATTS
144 153 160 169 178 184 188 200 -
CFM
1345 1305 1260 1220 1180 1125 1080 975 900
WATTS
258 273 272 283 292 298 306 310 320
CFM
1070 1030 980 935 870 775 720 665 -
WATTS
145 161 165 173 181 190 198 202 -
CFM
1285 1245 1205 1165 1110 1060 1005 910 860
WATTS
238 246 258 264 263 282 288 296 296
CFM
1505 1465 1420 1385 1335 1300 1250 1205 1150
WATTS
359 371 384 383 393 398 406 416 422
CFM
1035 995 945 895 845 790 695 630 580
WATTS
132 144 152 157 168 176 183 189 196
CFM
1410 1365 1330 1290 1250 1205 1155 1110 1065
WATTS
301 312 316 322 331 339 347 356 365
CFM
1545 1500 1465 1425 1385 1345 1310 1270 1225
WATTS
390 396 413 417 421 431 435 443 453
CFM
1355 1300 1250 1210 1155 1110 1045 965 905
WATTS
212 228 230 246 248 261 273 282 289
CFM
1655 1610 1575 1530 1485 1440 1395 1340 1285
WATTS
365 370 383 396 410 417 416 423 434
CFM
1895 1855 1805 1770 1730 1685 1640 1600 1565
WATTS
558 558 578 584 590 594 602 612 615
CFM
1360 1300 1260 1215 1175 1125 1085 1030 960
WATTS
213 221 233 244 255 264 273 293 304
CFM
1665 1630 1595 1555 1505 1475 1425 1380 1360
WATTS
385 405 410 409 429 441 448 454 471
CFM
2000 1960 1925 1875 1835 1800 1760 1725 1680
WATTS
642 651 660 651 672 683 691 699 695
DP14CM6041/43*
T1 230
T2/T3 230
T4/T5 230
DP14CM4841/43*
T1 230
T2/T3 230
T4/T5 230
DP14CM4241*
T1 230
T2/T3 230
T4/T5 230
DP14CM3641/43*
T1 230
T2/T3 230
T4/T5 230
230
DP14CM3041*
T1 230
T2/T3 230
T4/T5 230
Model Speed Volts
E.S.P (In. of H
2
O)
DP14CM2441*
T1 230
T2/T3 230
T4/T5