OPERATION MANUAL SPLIT SYSTEM Air Conditioners MODEL Ceiling suspended type FHQ18PVJU FHQ24PVJU FHQ30PVJU English Français Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with the equipment owner. Español Lire soigneusement ces instructions avant l’installation. Conserver ce manuel à portée de main pour référence ultérieure. Ce manuel doit être donné au propriétaire de l’équipement.
4 11 1 3 6 hr F hr 5 7 NOT AVAILABLE TEST 8 10 9 12 L H 13 20 19 TEST 18 17 16 14 15 21 1 f a e e i g h d d j 3 b d c e f hr F H k 2 4 [1] 00_CV_3PN07753-11N.indd Sec.
CONTENTS ILLUSTRATIONS .............................................. [1] 1. WHAT TO DO BEFORE OPERATION ......... 1 2. SAFETY CONSIDERATIONS ...................... 1 3. OPERATION RANGE ................................... 4 4. INSTALLATION SITE ................................... 4 5. NAME AND FUNCTION OF EACH SWITCH AND DISPLAY ON THE REMOTE CONTROLLER ............................................. 5 6. OPERATION PROCEDURE ........................ 5 7. OPTIMUM OPERATION .............................. 8 8.
WARNING ........ Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION ......... Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be sued to alert against unsafe practices. NOTE................ Indicates situation that may result in equipment or property-damage-only accidents. Keep these warning sheets handy so that you can refer to them if needed.
• Do not install the air conditioner at any place where flammable gas may leak out. If the gas leaks out and stays around the air conditioner, a fire may break out. • Operating the air conditioner with wet hands could result in a shock hazard. • Check the unit stand for damage on a continuous basis. If left in a damaged condition the unit may fall and cause injury. • Do not allow children to play on or around the unit as they could be injured.
• Arrange the drain pipe to ensure smooth drainage. Incomplete drainage may cause wetting of the building, furniture etc. • Do not place the controller exposed to direct sunlight. The LCD display may get discolored, failing to display the data. • Do not wipe the controller operation panel with benzine, thinner, chemical dustcloth, etc. The panel may get discolored or the coating peeled off. If it is heavily dirty, soak a cloth in water-diluted neutral detergent, squeeze it well and wipe the panel clean.
Regarding drainage of drain pipe • Is the drain pipe executed to perform complete drainage? If proper drainage is not carried out from the outdoor drain pipes during air-conditioning operation, chances are that dust and dirt are clogged in the pipe. This may result in a water leakage from the indoor unit. Under such circumstances, stop the operation of the air conditioner, and then consult your dealer or our service station. 5.
COOLING, HEATING, AUTOMATIC, FAN, AND PROGRAM DRY OPERATION Operate in the following order. OPERATION MODE SELECTOR 1 Press OPERATION MODE SELECTOR button several times and select the OPERATION MODE of your choice as follows. COOLING OPERATION ............................... “ ” HEATING OPERATION................................. “ ” AUTOMATIC OPERATION ............................“ ” • In this operation mode, COOL/HEAT changeover is automatically conducted. FAN OPERATION .........................
AIR FLOW DIRECTION ADJUST • There are 2 ways of adjusting the air discharge angle. 1. A. Up and down direction 2. B. Left and right direction A. Up and down direction B. Left and right direction A. UP AND DOWN DIRECTION Press the AIR FLOW DIRECTION ADJUST button to select the air direction as shown below. swing The AIR FLOW FLAP display swings as shown below and the air flow direction continuously varies.
When the timer is programmed to stop the system after 3 hours and start the system after 4 hours, the system will stop after 3 hours and then 1 hour later the system will start. • After the timer is programmed, the display shows the remaining time. • Press the TIMER ON/OFF button once again to cancel programming. The display vanishes. 7. OPTIMUM OPERATION Observe the following precautions to ensure the system operates. • Adjust the room temperature properly for a comfortable environment.
3. Clean the air filter. Use vacuum cleaner A) or wash the air filter with water B). A) Using a vacuum cleaner (Do not use air of 120°F or higher.) B) Washing with water When the air filter is very dirty, use soft brush and neutral detergent. (Do not use water of 120°F or higher.) Remove water and dry in the shade. NOTE • Do not wash the air conditioner with hot water of more than 120°F, as doing so may result in discoloration and/or deformation.
Clean the air filter and outside panels • After cleaning the air filter, make sure to attach it. Turn on the main power supply switch • The display on the remote controller will be shown when the power is turned on. • To protect the unit, turn on the main power switch at least 6 hours before operation. WHAT TO DO WHEN STOPPING THE SYSTEM FOR A LONG PERIOD Turn on FAN OPERATION for a half day and dry the unit. • Refer to “FAN OPERATION”. Cut off the power supply.
• A “Shuh” sound which is heard at the start or immediately after the stop of operation or which is heard at the start or immediately after the stop of DEFROST OPERATION. This is the noise of refrigerant caused by flow stop and flow change. • A “Pishi-pishi” squeaking sound is heard when the system is in operation or after the stop of operation. Expansion and contraction of plastic parts caused by temperature change makes this noise. V.
3. The system operates but it does not sufficiently cool or heat. • If the air inlet or outlet of the indoor or the outdoor unit is blocked with obstacles. Remove the obstacle and make it well-ventilated. • If the air filter is clogged. Ask a qualified service person to clean the air filters. (Refer to “MAINTENANCE”) • If the set temperature is not proper. (Refer to “ADJUSTMENT”) • If the FAN SPEED button is set to LOW SPEED. (Refer to “ADJUSTMENT”) • If the air flow direction is not proper.
3PN07753-11N EM08A092 00_CV_3PN07753-11N.