Operation Manual

9
English
To set the clock
* Time cannot be set during unit operation.
1. Press .
Do not hold the button.
is displayed.
blinks.
2. Press .
Holding the button changes the time faster.
3. Press .
blinks.
is displayed.
Setting is complete.
NOTE
If other messages than time appear on the display with the step 1 operation, do not operate the button for about 60 seconds. The display will return to normal.
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save
energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling
(heating) effect.
Clogged air lters cause inefcient operation and waste energy.
Periodically clean the lter.
Recommended temperature setting
For cooling : 79°F – 82°F (26°C – 28°C)
For heating : 68°F – 72°F (20°C – 22°C)
Notes on the operating conditions
The air conditioner always consumes a small amount of electricity
even while it is not operating.
If you are not going to use the air conditioner for a long period, for
example in spring or autumn, turn the breaker off.
When the outdoor temperature is below 5°F (–15°C), turn on the
breaker more than 1 hour before starting the operation.
(This is to warm up the compressor.)
Running the unit under conditions not listed below may cause the
safety device to activate, stopping the unit. Also, condensation may
form on the indoor unit and drip. (DRY/COOLING operation)
MODE Operating conditions
COOLING
Outdoor temperature : 14 to 109°F (–10 to 43°C)
Indoor temperature : 64 to 90°F (18 to 32°C)
Indoor humidity : 80% max.
HEATING
Outdoor temperature : –4 to 75°F (–20 to 24°C)
Indoor temperature : 50 to 86°F (10 to 30°C)
Indoor humidity : 70% max.
DRY
Outdoor temperature : 50 to 108°F (10 to 42°C)
Indoor temperature : 64 to 86°F (18 to 30°C)
Indoor humidity : 80% max.
01_EN_3P226009-1A.indd 9 10/29/2012 2:11:52 PM