Service Manual
Table Of Contents
SiUS121502E Functions
List of Functions 5
Category Functions
FFQ09/12/15/18LVJU
Category Functions
FFQ09/12/15/18LVJU
Basic
Function
Inverter (with inverter power control)
z
Health &
Clean
Air-purifying filter —
Operation limit for cooling (°CDB) — Photocatalytic deodorizing filter —
Operation limit for cooling (°FDB) —
Air-purifying filter with photocatalytic
deodorizing function
—
Operation limit for heating (°CWB) —
Operation limit for heating (°FWB) —
Titanium apatite photocatalytic
air-purifying filter
—
PAM control —
Compressor Oval scroll compressor — Longlife filter (option)
z
Swing compressor — Air filter (prefilter) —
Rotary compressor — Wipe-clean flat panel —
Reluctance DC motor — Washable grille
z
Comfortable
Airflow
Power-airflow flap (horizontal blade) — Filter cleaning indicator
z
Power-airflow dual flaps — Good-sleep cooling operation —
Power-airflow diffuser — Timer WEEKLY TIMER operation
z
2
Wide-angle louvers (vertical blades) — 24-hour ON/OFF TIMER —
Auto-swing (up and down)
z
72-hour ON/OFF TIMER
z
1
Auto-swing (right and left) — NIGHT SET mode —
3-D airflow — Worry Free
(Reliability &
Durability)
Auto-restart (after power failure)
z
COMFORT AIRFLOW operation — Self-diagnosis (R/C, LED)
z
Comfort
Control
Auto fan speed — Wiring error check function —
Indoor unit quiet operation —
Anti-corrosion treatment of outdoor heat
exchanger
—
NIGHT QUIET mode (automatic) —
OUTDOOR UNIT QUIET operation (manual) — Flexibility Multi-split / split type compatible indoor unit —
INTELLIGENT EYE operation — Flexible power supply correspondence —
Quick warming function — High ceiling application —
Hot-start function
z
Chargeless —
Automatic defrosting — Either side drain (right or left) —
Operation Automatic operation
z
Power selection —
Program dry function
z
°F/°C changeover R/C temperature display
(factory setting: °F)
z
2
Fan only
z
Lifestyle
Convenience
New POWERFUL operation
(non-inverter)
—
Remote
Control
5-room centralized controller (option) —
Remote control adaptor
(normal open pulse contact) (option)
—
Inverter POWERFUL operation —
Priority-room setting —
Remote control adaptor
(normal open contact) (option)
—
COOL / HEAT mode lock —
HOME LEAVE operation — DIII-NET compatible (adaptor) (option)
z
ECONO operation — Remote
Controller
Wireless (option)
z
Indoor unit ON/OFF button
z
1 Wired (option)
z
Signal receiving sign
z
1
R/C with back light
z
2
Temperature display —
Note:
z
: Available
— : Not available
1: With wireless remote controller