Service Manual

SiUS121502E Indoor Unit
Printed Circuit Board Connector Wiring Diagram 25
Sensor PCB
(PCB1)
Service PCB
(PCB3)
Display PCB
(PCB4)
LED3 does not function.
Note: The symbols in the parenthesis are the names on the appropriate wiring diagram.
1) S49 Connector for control PCB
2) RTH2 (R1T) Room temperature thermistor
S49
RTH2
3P191450-1
1) S27 Connector for control PCB
2) SW2 (S2W)-4 Switch for upward airflow limit setting
Refer to page 191 for detail.
Keep the other switches as factory setting.
3) SW4 (S4W) Switch for airflow selection
Refer to page 38 for detail.
S27
SW4
SW2-4
3P191448-1
1) S47 Connector for control PCB
2) SW1 (S1W) Forced cooling operation ON/OFF button
3) LED1 (H1P) LED for operation (green)
4) LED2 (H2P) LED for timer (yellow)
S47SW1LED2
LED1
3P191447-1