Function of CTXS, FTXS, CDXS, FDXS, FVXS Series SiUS121502E
36 Function and Control
Frequency Limits The following functions regulate the minimum and maximum frequency:
Forced Cooling
Operation
Refer to page 178 for detail.
1.3 Airflow Direction Control (CTXS, FTXS, FVXS Series)
Power-Airflow
Dual Flaps
The large flap sends a large volume of air downward to the floor and provides an optimum control in
cooling, dry, and heating operation.
<Cooling / Dry>
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown far
and distributed all over the room.
<Heating>
During heating operation, the large flap directs airflow downward to spread the warm air to the
entire room.
Wide-Angle
Louvers
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees a
comfortable air distribution.
Auto-Swing The following table explains the auto swing process for cooling, dry, heating, and fan:
CTXS, FTXS Series
Frequency Functions
Low Four way valve operation compensation. Refer to page 65.
High Compressor protection function. Refer to page 66.
Discharge pipe temperature control. Refer to page 66.
Input current control. Refer to page 67.
Freeze-up protection control. Refer to page 68.
Heating peak-cut control. Refer to page 68.
Defrost control. Refer to page 70.
Flap (up and down)
Louver
(right and left)
Cooling / Dry Heating Fan