DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL Deutsch English 3PEN393185-2D.
CE - DECLARACION-DE-CONFORMIDAD CE - DICHIARAZIONE-DI-CONFORMITA CE - ∆HΛΩΣΗ ΣΥΜΜΟΡΦΩΣΗΣ 19 ob upoštevanju določb: 20 vastavalt nõuetele: 21 следвайки клаузите на: 22 laikantis nuostatų, pateikiamų: 23 ievērojot prasības, kas noteiktas: 24 održiavajúc ustanovenia: 25 bunun koşullarına uygun olarak: 07 ** 08 ** 09 ** 10 ** 11 ** 12 ** 11 Information * enligt och godkänts av enligt Certifikatet . 12 Merk * som det fremkommer i og gjennom positiv bedømmelse av ifølge Sertifikat .
English Safety Precautions • The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety. Be sure to observe all precautions without fail. • Meaning of WARNING and CAUTION notices WARNING.....Failure to follow these instructions properly may result in personal injury or loss of life. CAUTION......
3PEN393185-2D.book Page 2 Tuesday, April 7, 2015 8:51 AM • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial and household use by lay persons. • Sound pressure level is less than 70 dB(A). Accessories Indoor unit A – H A Mounting plate 1 D Remote controller holder 1 G Operation manual 1 B Titanium apatite photocatalytic air-purifying filter 2 E Dry battery AAA.
1. Removing and installing the front panel English Preparation before Installation Indentations on the main unit • Removal method 1) Place your fingers in the indentations on the main unit (one each on the left and right sides), and open the front panel until it stops. 2) Continue to open the front panel further while sliding the panel to the right and pulling it toward you in order to disengage the front panel shaft on the left side.
3PEN393185-2D.book Page 4 Tuesday, April 7, 2015 8:51 AM Indoor Unit Installation Drawings How to attach the indoor unit Hook the hooks of the bottom frame to the A mounting plate. If the hooks are difficult to hook, remove the front grille. A Mounting plate How to remove the indoor unit Push up the marked area (at the lower part of the front grille) to release the hooks. If it is difficult to Front grille release, remove the front grille.
1. English Indoor Unit Installation Installing the mounting plate • The mounting plate should be installed on a wall which can support the weight of the indoor unit. 1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the boring points on the wall. 2) Secure the mounting plate to the wall with screws.
3PEN393185-2D.book Page 6 Tuesday, April 7, 2015 8:51 AM Indoor Unit Installation • Remove the pipe port cover as shown below. 1) Cut off the pipe port cover from inside the front grille using a copping saw. Apply the blade of the copping saw to the notch, and cut off the pipe port cover along the uneven inner surface. 2) After cutting off the pipe port cover, perform filing. Remove the burrs along the cut section using a half round needle file.
English Indoor Unit Installation 3-2. Left-side, left-back, or left-bottom piping How to replace the drain plug and drain hose • Replacing onto the left side Drain hose attachment position 1) Remove the insulation fixing screw on the right and remove the drain hose. 2) Remove the drain plug on the left side and attach it to the right side. 3) Insert the drain hose and tighten with included insulation fixing screw. * (Forgetting to tighten this may cause water leakages.
3PEN393185-2D.book Page 8 Tuesday, April 7, 2015 8:51 AM Indoor Unit Installation Wiring diagram : Terminal strip : Connection : Connector : Field wiring BLK : Black ORG : Orange BLU : Blue RED : Red BRN : Brown WHT : White GRN : Green YLW : Yellow Notes : Refer to the nameplate for power requirements.
4. English Indoor Unit Installation Wiring 1) Strip wire ends (15mm). 2) Match wire colours with terminal numbers on indoor and outdoor unit’s terminal blocks and firmly screw wires to the corresponding terminals. 3) Connect the earth wires to the corresponding terminals. 4) Pull wires to make sure that they are securely latched up, then retain wires with wire retainer. 5) Shape the wires so that the service lid fits securely, then close service lid.
3PEN393185-2D.book Page 10 Tuesday, April 7, 2015 8:51 AM Indoor Unit Installation 5. Drain piping The drain hose should be inclined downward. 1) Connect the drain hose, as described right. No trap is permitted. Do not put the end of the hose in water. 2) Remove the air filters and pour some water into the drain pan to check the water flows smoothly. 3) If drain hose extension or embedded drain piping is required, use appropriate parts that match the hose front end.
2. English Refrigerant Piping Work Refrigerant piping CAUTION • Use the flare nut fixed to the main unit. (To prevent cracking of the flare nut by aged deterioration.) • To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.) • Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage. Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand.
3PEN393185-2D.book Page 12 Tuesday, April 7, 2015 8:51 AM Trial Operation and Testing 1. Trial operation and testing • Trial operation should be carried out in either COOL or HEAT operation. 1-1. Measure the supply voltage and make sure that it is within the specified range. 1-2. In COOL operation, select the lowest programmable temperature; in HEAT operation, select the highest programmable temperature. 1-3.
Copyright 2014 Daikin 3PEN393185-2D.book Page 1 Tuesday, April 7, 2015 8:51 AM 3P393185-2D 2015.