Installation Instructions

8 English
Indoor Unit Installation
Wiring diagram
Wiring diagram parts table
: Terminal strip : Connection
: Connector : Field wiring
BLK : Black ORG : Orange
BLU : Blue RED : Red
BRN : Brown WHT : White
GRN : Green YLW : Yellow
Notes
: Refer to the nameplate for power requirements.
: INDOOR Indoor
: OUTDOOR Outdoor
: RECTIFIER Rectifier
: TRANSMISSION CIRCUIT Transmission circuit
: WIRELESS REMOTE CONTROLLER Wireless remote controller
: SIGNAL RECEIVER Signal receiver
FG.......................... Frame ground
FU1........................ Fuse (3,15A)
H1~H3 ................... Harness
H1P, H2P ............... Pilot lamp
MR10 ..................... Magnetic relay
M1F........................ Fan motor
M1S ....................... Swing motor
PCB1~PCB3.......... Printed circuit board
R1T,R2T................. Thermistor
S6~S602................ Connector
S1W....................... Operation switch
V2 .......................... Varistor
X1M ....................... Terminal strip
Z1C........................ Ferrite core
....................... Protective earth
CAUTION
Note that operation will restart automatically if the
main power supply is turned off and then back on again.
HIGH VOLTAGE – be sure to discharge the capacitor completely
before repair work.
Risk of failure or water leakage!
Do not wash the inside of the air conditioner by yourself.
3PEN393185-2D.book Page 8 Tuesday, April 7, 2015 8:51 AM