Service manual

Field Settings SiBE05-722_C
112 Trial Operation and Field Settings
4. Field Settings
4.1 When 2 Units are Installed in 1 Room
Outline When 2 indoor units are installed in 1 room, 1 of the 2 indoor units and the corresponding
wireless remote controller can be set for different addresses.
Both the indoor unit PCB and the wireless remote controller need alteration.
Indoor Unit PCB
Cut the address setting jumper JA on the control PCB.
Caution Replace the PCB if you accidentally cut a wrong jumper.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
Wireless Remote
Controller
Cut the address setting jumper.
ADDRESS JA
EXIST 1
CUT 2
(R12419)
Address
EXIST
CUT
1
2
Jumper
(R14202)