Service manual

Piping Diagrams SiBE05-722_C
120 Appendix
1.2.2 Heat Pump
RXS25/35E2V1B
RXS25/35G2V1B, RXS25/35G2V1B9, RXS25/35J2V1B, RXS25K3V1B, RXS35K2V1B
M
9.5CuT
MUFFLER
PROPELLER FAN
7.9CuT
7.9CuT
COMPRESSOR
9.5CuT
ACCUMULATOR
9.5CuT
9.5CuT
7.0CuT
7.0CuT
OUTDOOR UNIT
HEAT EXCHANGER
4.8CuT
4.8CuT
6.4CuT 6.4CuT
MUFFLER
9.5CuT
6.4CuT
FIELD PIPING
FIELD PIPING
(
6.4CuT
)
(
9.5CuT
)
φ
4.0
×
ID. 2.0CuT
REFRIGERANT FLOW
COOLING
HEATING
9.5CuT
DISCHARGE PIPE
THERMISTOR
GAS STOP
VALVE
LIQUID STOP
VALVE
MOTOR OPERATED
VALVE
HEAT EXCHANGER
THERMISTOR
OUTDOOR TEMPERATURE
THERMISTOR
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
FOUR WAY
VALVE
ON
:
HEATING
3D047316R
OUTDOOR UNIT
HEAT EXCHANGER
7.0CuT
7.0CuT
9.5CuT
EV
4.8CuT
6.4CuT
6.4CuT
4.8CuT
M
PROPELLER FAN
9.5CuT
9.5CuT
6.4CuT
7.9CuT
9.5CuT
MUFFLER
9.5CuT 9.5CuT
COMPRESSOR
MUFFLERMUFFLER
7.9CuT
ACCUMULATOR
REFRIGERANT FLOW
COOLING
HEATING
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
DISCHARGE PIPE
THERMISTOR
GAS STOP
VALVE
LIQUID STOP
VALVE
FIELD PIPING
(6.4CuT)
FIELD PIPING
(9.5CuT)
MUFFLER
WITH
FILTER
φ.4.0×ID. 2.0CuT
ELECTRONIC
EXPANSION
VALVE
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
FOUR WAY
VALVE
ON: HEATING
3D059586Q