20 Printed Circuit Board Connector Wiring Diagram
2.2 RK(X)S25/35G2V1B
Main PCB
Caution Replace the PCB if you accidentally cut the jumpers other than J5 and J8.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of
them.
1) S10 Connector for filter PCB
2) S20 Connector for electronic expansion valve coil
3) S30 Connector for compressor
4) S40 Connector for overload protector
5) S50 Connector for magnetic relay
6) S70 Connector for fan motor
7) S80 Connector for four way valve coil
8) S90 Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
9) HL3, HN3 Connector for filter PCB
10)HR2 Connector for reactor
11)FU1, FU2 Fuse (3.15 A, 250 V)
12)LED A LED for service monitor (green)
13)V1 Varistor
14)J5 Jumper for improvement of defrost performance
Refer to page 115 for detail.
15)J8 Jumper for facility setting
Refer to page 113 for detail.
16)SW1 Forced cooling operation ON/OFF button
Refer to page 110 for detail.