Specifications

ED72-975 Specifications
BRC1E61 9
2. In the case of Centralised remote controller connection.
When connecting a centralised related device(*1), Schedule, Limit Operation and Home Leave
functions cannot be set.
(*1) this means All Centralised remote controller.
intelligent Touch Controller [DCS601C51]
intelligent Manager [DAM602B51,52]
Parallel interface [DPF201A51,52,53]
Central remote controller [DCS302CA51]
Unified ON/OFF controller [DCS301BA51]
Schedule timer [DST301BA51]
Residential central remote controller [DCS303A51]
Wiring adaptor for electrical appendices KRP2A5*/6*]
3. Quick Cooling/Heating <restriction for SkyAir only>
Under the following conditions, Quick Cooling/Heating operation stops to return to the normal operation.
· When the room temperature reaches to the set temperature, the thermostat turns OFF and the unit
returns to the normal operation.
· After 30 minutes past from the operation start, the unit returns to the normal operation.
3. Specifications
New Remote Controller
BRC1E61
Dimension (mm)
H × W × D
120 × 120 × 19
LCD
Display size (mm)
H × W
45.4 × 71.4
Display method Full dot method (dot 160 × 255)
Backlight
Yes
(Background color: white)
Color Fresh white
Cover for operation part No