Service Manual

SiUS091133 Main Functions
Function and Control 30
Frequency Limits The following functions regulate the minimum and maximum frequency:
Forced Cooling
Operation
Refer to page 384 for detail.
1.3 Airflow Direction Control (FTXS Series)
Power-Airflow
Dual Louvers
The large louver sends a large volume of air downward to the floor and provides an optimum
control in cooling, dry, and heating operation.
<Cooling / Dry>
During cooling or dry operation, the louver retracts into the indoor unit. Then, cool air can be blown
far and distributed all over the room.
<Heating>
During heating operation, the large louver directs airflow downward to spread the warm air to the
entire room.
Wide-Angle Fins The fins, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Auto-Swing The following table explains the auto swing process for cooling, dry, heating, and fan:
Frequency Functions
Low Four-way valve operation compensation. Refer to page 45.
High Compressor protection function. Refer to page 46.
Discharge pipe temperature control. Refer to page 46.
Input current control. Refer to page 47.
Freeze-up protection control. Refer to page 48.
Heating peak-cut control. Refer to page 48.
Defrost control. Refer to page 50.
Vertical Swing (up and down)
Horizontal Swing
(right and left)
Cooling / Dry Heating Fan
09/12 class