Troubleshooting
These incidents are not malfunctions.
The following incidents do not indicate a malfunctioning air conditioner and have explanations. The air conditioner can continue
to operate.
Indoor unit
Outdoor unit
The HEAT operation stops suddenly
and a owing sound is heard.
The outdoor unit is taking away the frost. The HEAT
operation starts after the frost on the outdoor unit is
removed. You should wait for about 4 to 12 minutes.
Operation does not start soon.
When “ON/OFF” button was pressed soon after
operation was stopped.
When the mode was reselected.
This is to protect the air conditioner.
You should wait for about 3 minutes.
Possible sounds.
Flowing water
Generated because the refrigerant in the air
conditioner is owing.
This is a pumping sound of the water in the air
conditioner it is heard when the water is pumped out
from the air conditioner in cooling or drying operation.
The refrigerant ows in the air conditioner even if
the air conditioner is not working when the indoor
units in other rooms are in operation.
Blowing
Generated when the ow of the refrigerant in the
air conditioner is switched over.
Ticking
Generated when the size of the air conditioner slightly
expands or shrinks as a result of temperature changes.
Whistling sound
Generated when refrigerant ows during defrosting operation.
Clicking sound during operation or idle time
Generated when the refrigerant control valves or
the electrical parts operate.
Clopping sound
Heard from the inside of the air conditioner when the
exhaust fan is activated while the room doors are closed.
Open the window or turn off the exhaust fan.
The outdoor unit emits water or steam.
In HEAT operation
The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrost operation.
In COOL or DRY operation
Moisture in the air condenses into water on the cool surface of outdoor unit
piping and drips.