User`s manual

17
18
Cooling
only
Heat
pump
Horizontal Flow
0°
0°
Settable to 5 different levels
between
0° and 35°
Settable to 5 different levels
between 0° and 60°
Settable to 5 different levels
between 25° and 60°
Auto-swing
between 0° and 35°
Auto-swing
between 0° and 60°
Auto-swing
between 25° and 60°
Draft
prevention
setting
(Set on site)
(Set on site)
Standard
setting
Setting to
prevent
soiling of
ceiling
Conditioned air is distributed
evenly by Auto-swing
operation.
Adjustable airflow angle to
suit all room conditions.
AUTO-SWING
0°
0°
0°
25°
60°
60°
0°
35°
25°
60°
35°
60°
5 directions
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
Even for modules other than 600 x 600, no inspection
opening is required. Maintenance can be performed after
simply removing the grille, because the switchbox is built
into the unit.
T-bar grid does not need to be cut
575 mm
575 mm
700 mm
700 mm
286
mm
Compact
decoration panel
T bar
600 mm
600 mm
Ceiling panel
Spiral hub cover
At low fan speeds, the 2.5
kW model produces sound
of only 24.5 dB (A), and
even the 6.0 kW model as
low as 32 dB (A). This is due
to a spiral hub cover that
reduces internal airflow
resistance.
Option Option
Wireless remote
controller and signal
receiver unit are
sold as a set.
Signal receiver unit
Wireless LCD
remote controller
Wired LCD
remote controller
5.0
kW class
FFQ50BV1B
FFQ50BV1B
3.5
kW class
FFQ35BV1B
FFQ35BV1B
2.5
kW class
FFQ25BV1B
FFQ25BV1B
6.0
kW class
FFQ60BV1B
FFQ60BV1B
FFQ25
29.5/24.5 dB(A)
FFQ35
32/25 dB(A)
FFQ50
36/27 dB(A)
FFQ60
41/32 dB(A)
(H/L)
4-way flow
1 pattern
3-way flow
4 patterns
2-way flow
1 pattern
" " denotes piping direction. " " denotes sealing member for air discharge
outlet (option).
Note: For 3-way or 2-way flow installation, the sealing member for air
discharge outlet (option) must be used to close off the unused outlet(s).
Air discharge patterns can be selected
according to installation.
Multi-Flow System
Quiet sound level of only 24.5 dB (A)
Two selectable temperature sensors
Both indoor unit and wired remote controller (option)
contain temperature sensors. Temperature sensing
can be set at the unit or, to further improve comfort
level, closer to the target area at the wired remote
control. This feature requires initial setting by the
installer.
*Temperature sensor on indoor unit must be used when the air conditioner
is controlled from another room.
(Wireless remote controller does not have a temperature sensor.)
The filter has sanitary, mould-resistant treatment.
Mould-resistant treatment for filter
If there is a power failure while the unit is operating,
the system will restart in the same mode when
power is restored.
Auto-restart
Maintenance is not required for one year.
Long-life filter
When the filter requires cleaning, the filter icon is
displayed on the remote controller.
Filter sign
Programme "Dry"
Programme Dry gives priority to reducing the level of
humidity rather than room temperature.
Dehumidification is computer controlled to prevent
abrupt and uncomfortable changes in air temperature.
Switchable fan speed: High/Low
Uncomfortable cold air draft is not discharged when
heating operation starts or when switching to heat
after defrosting.
Hot start (after defrost)
Note:
Operation sound
increases when using
2-way or 3-way flow.
Provided with drain pump
750 mm
Daikin's innovative air discharge mechanism keeps
airflow away from the ceiling. Ceiling cleaning is
required less frequently.
Ceiling soiling prevention function
Compact Multi Flow Ceiling-Mounted Cassette Type
Low draft performance is
designed for your comfort
Designed to fit 600 mm wide
ceiling grids
Comfortable across all areas
Indoor unit lineup Indoor unit lineup
Less draught
*
* Heat pump only