Operation Manual
41
Storingen opsporen en oplossen
■
LED OP PRINTPLAAT VAN DE BUITENUNIT
serie 3MXS-, 4MXS-, 5MXS
GROEN ROOD
MICROCOMPUTER
NORMAAL
DETECTIE VAN
STORING
LED-A LED1 LED2 LED3 LED4 LED5 DIAGNOSE
● ● ● ● ●
NORMAAL CONTROLEER BINNENUNIT
● ●
HOGEDRUKBEVEILIGING WERKTE OF BEVROOR IN DE
BEDRIJFS- OF DE STAND-BYUNIT
●
●
●
* OVERBELASTINGRELAIS WERKTE OF HOGE TEMPERATUUR
AFVOERBUIS
●
●
●
STORING BIJ START COMPRESSOR
● ● ●
OVERSTROOM INPUT
● ● ●
* THERMISTOR OF CT REAGEREN ABNORMAAL
● ●
HOGE TEMPERATUUR SCHAKELKAST
● ● ● ●
HOGE TEMPERATUUR KOELVINNEN OMVORMERCIRCUIT
● ● ● ●
* OVERSTROOM op UITGANG
● ● ●
* TEKORT AAN KOELMIDDEL
● ● ●
LAGE SPANNING VOOR HOOFDCIRCUIT OF TIJDELIJK
SPANNINGSVERLIES
● ● ● ●
OMSCHAKELSTORING OMKERING ELEKTROMAGNETISCHE KLEP
●
STORING VENTILATORMOTOR
− − − −
●
[NOOT 1]
●
− − − −
●
STORING STROOMTOEVOER OF [NOOT 2]
NOOT: LED5 is alleen beschikbaar in de 5M-serie.
GROEN FLITST NORMAAL
ROOD NORMAAL UIT
AAN
KNIPPERT
●
UIT
−
IRRELEVANT
■
LED OP PRINTPLAAT VAN DE BUITENUNIT
2MXS-serie
GROEN
MICROCOMPUTER NORMAAL
LED-A DIAGNOSE
NORMAAL CONTROLEER BINNENUNIT
[NOOT 1]
●
STORING STROOMVOORZIENING OF [NOOT 2]
GROEN FLITST NORMAAL
AAN
KNIPPERT
●
UIT
NOOT
• Schakel de stroom uit en dan opnieuw in. Als het LED-display terugkomt, heeft de printplaat van de buitenunit een storing.
• Gemarkeerde diagnose
* Niet van toepassing voor sommige gevallen. Zie de servicegids voor meer bijzonderheden.