English Wired Remote Controller Installation Manual - + MODEL BRC1H71W • Be sure to read before conducting the installation of this product, and conduct installation according to this manual. • Refer to this manual together with the installation manual of the indoor unit. It is possible to perform settings of some functions from a smart phone app. 01_EN_EM19A026_IM.
01_EN_EM19A026_IM.
Contents Safety Considerations......................................................... 2 Accessories......................................................................... 3 Remote controller installation procedure............................. 4 Button Locations and Descriptions.................................... 11 Overview of screens.......................................................... 12 Setting screen list.............................................................. 13 Names and Functions.....
Safety Considerations The original instructions are written in English. All other languages are translations of the original instructions. All phases of the field-installation, including, but not limited to, electrical, piping, safety, etc. must be in accordance with manufacturer’s instructions and must comply with national, state, provincial and local codes. Read these SAFETY CONSIDERATIONS carefully before installing the remote controller.
CAUTION Do not install the remote controller in the following locations: (a) Where a mineral oil mist or oil spray or vapor is produced, for example, in a kitchen. Plastic parts may deteriorate. (b) Where corrosive gas, such as sulfurous acid gas, is produced. (c) Near machinery emitting electromagnetic waves. Electromagnetic waves may disturb the operation of the control system and cause the unit to malfunction.
Remote controller installation procedure Deciding where to install the remote controller Select the installation location based on “Safety Considerations” (see page 2) and obtain consent of the customer. Creating a wiring through-hole in the wall (when opening a hole in the wall and installing) [Unit : inch (mm)] 3-11/64 (80.5) 1-47/64 (44) 13/64 (5) 41/64 (16.25) 33/64 (13) R3/32(2.5) R3/32(2.5) Access hole 9/32 (7) 35/64 (13.75) Access hole 1-47/64 (44) Back plate Through-hole 3-11/64 (80.
Determining the wire routing direction for the back plate Before mounting the controller, determine the wiring direction and remove a piece of the controller’s back plate accordingly (i.e.: a, b, c). The wiring can be routed from the top, the left, or the bottom of the back cover. Remove a piece of the back plate according to the following figure. After removing a thin piece with a tool such as clippers, remove burrs using a file, etc.
Securing the back plate Wall installation 1 : Take the drywall screws and drywall anchors out of the accessory bag. 2 : Mount the back plate to a flat surface. Drywall anchors Drywall screws In case of installing in the electrical component box 1 : Take the screws for the mounting plate (M3.5×10 and M4×40), and the mounting plates (metal and plastic) out of the accessory bag. 2 : Attach the mounting plate (metal) to the electrical component box with the screws for the mounting plate (M4×40).
Connecting the electrical wiring All wiring must comply with the following requirements: Wire specification Value Wiring type Non-shielded, 2-conductor, Stranded copper wire Wiring size AWG-18 Wiring length Maximum 1640 feet (500 m) Prepare the wiring for connection to the remote controller following these instructions: Approx. 3/8 inch (10 mm) L To simplify the wiring, maintain a 3/8 inch (10 mm) difference Remove the wire jacket between the length of the two and insulation conductors.
Top outlet P1P2 P1P2 terminal Rear outlet P1P2 Left outlet P1P2 8 English 01_EN_EM19A026_IM.
Bottom outlet P1P2 CAUTION • Keep the wiring away from the power wire so that electrical noise (external noise) is not received. • In order to prevent the entry of water or insects, use putty (field supply) to securely seal the wiring lead-in hole. Closing the controller 1 : Place the top of the controller on the top of the back plate. 2 : Snap the bottom of the controller into place on the bottom of the back plate. 3 : Ensure the installation site is dust‑free, before peeling the protective seal.
When removing the upper casing Insert a flat head screwdriver into the recess in the back plate and remove the upper casing. (2 locations) CAUTION • The remote controller circuit board is attached to the upper casing. Be careful not to damage the circuit board and casing when removing the upper casing. • Do not touch the remote controller circuit board directly with your hands. • Be careful not to allow dust or moisture to adhere to the circuit board when the upper casing is removed.
Button Locations and Descriptions a c b - + d e f Functions items (i.e., Operation Mode, Fan Speed, and Setpoint) are set from the menu screen. NOTICE • Do not install the remote controller in places exposed to direct sunlight. The LCD may be damaged. • Do not pull or twist the remote controller cord. The remote controller may be damaged. • Do not use objects with sharp ends to press the buttons on the remote controller. Damage may result. a ON/OFF button • Press this button to turn on the system.
Overview of screens How to display the screen The following is just an example. The items available for setting vary depending on the indoor unit you are using. If there is no button operation for about 10 seconds, the screen returns to the home screen. Change setpoint screen Press or Auto Cool Set Home screen 74 User menu Press Auto Cool Room Press This screen is used for setting the setpoint. Select press 73 , then Select press . , then . , then . This screen is a menu for the user.
Setting screen list Setting list Name Icon Description User Administrator Installer menu menu menu Depends on current setting Operation Mode Operation mode setting Depends on current setting Fan Speed Airflow rate setting Depends on current setting Airflow Direction Airflow direction 1 setting Depends on current setting Vertical Airflow Airflow direction 2 setting Depends on current setting Ventilation Mode Ventilation mode setting Depends on current setting Ventilation Ra
Setting list Name Icon Description User Administrator Installer menu menu menu Bluetooth Setting Bluetooth setting Backlight Backlight brightness setting Contrast Contrast setting Clock Setting Clock setting Standard Temp Scale reference temperature setting About Administrator information Admin Password Administrator password setting Installer Password Installer password setting Field Setting Field Setting R/C Setting R/C Setting Addres
Names and Functions Screen display explanation a Operation mode/OFF display Home screen • Displays the operation status. a b Error/Filter/Test icon b c d e f Auto Cool Room 73 STANDBY SETBACK g h i j k • Error, filter and test icons are displayed. c Room/Set • Indicates whether it’s a room temperature display (Room) or setpoint display (Set). d Room temperature/Set temperature • Displays the current room or setpoint temperature. l e Fan speed • Displays the set fan speed.
Starting up the system • Check for completion of indoor/outdoor unit wiring. • Ensure that covers is closed on electrical component boxes for both indoor and outdoor units prior to restoring power. Power-on • The controller gets its power from the indoor unit. • Therefore, for the controller to be operable, make sure the indoor unit is powered on. Once the controller is powered, it will automatically startup.
INFORMATION If a sub controller does not display the home screen 2 minutes after its designation, turn off the power and check the wiring. INFORMATION After re-designating a controller, the system requires a power reset. INFORMATION The following functions are not available for sub controllers: • “Auto” operation mode • Individual airflow direction • Filter auto clean • Setback temperature setpoints • Draft prevention English 17 01_EN_EM19A026_IM.
Designating a controller as main or sub Prerequisite: A remote controller is already connected to the indoor unit. Connect a second controller. After turning on the power, perform setting of the second controller. Result: It will start up automatically. Home screen Wait for a U5 or U8 error code to appear on the screen. Screen display explanation 1 main 2 sub U5 1 Home screen When the U5 error code appears, press “2” appears on the screen.
Switching the Changeover Master About the changeover master When multiple indoor units are connected to one outdoor unit or branch selector unit, by giving the authority to switch the operation mode to a specific indoor unit, the operation switching of other indoor units can be controlled. • Only the remote controller set as the changeover master can select cooling, heating or auto operation modes. • Remote controllers not set as the changeover master will follow the operation mode of the changeover master.
Heat pump system When multiple indoor units are connected to 1 outdoor unit: Give the authority to choose cooling, heating, or auto to 1 of these remote controllers. a b b c b c b c c Cool Cool d e a b c d e Outdoor unit Indoor unit Remote controller Changeover master Changeover mode follower • For the remote controller without cooling/heating selection authority, the operation modes that can be selected are limited.
Releasing the changeover master To change the authority to choose cooling/heating, you must first specify the remote controller with the authority, then release the authority. Depending on the system, setting may not be available. Prerequisite: You are in the installer menu. You are operating the controller of the indoor unit that you want to release from being the changeover master.
Setting up the changeover master This setting is available only when none of the remote control in the system has master control. Prerequisite: No indoor unit is yet set as the changeover master (“ ” icon blinking on all controllers). You are operating the controller of the indoor unit that you want to set as the changeover master. Cool Room 73 Menu screen Navigate to the “Operation Mode” menu. Operation Mode Text mode Icon mode Sub-menu screen Press or .
Installer Menu How to enter the Installer menu Installer menu screen Home screen Auto Cool Room 73 ˚F 73 74 Text mode Icon mode Press and hold button for 5 seconds or longer to display the information screen. Information screen 12:34 Press (in that order) and hold them down for 10 seconds. The installer menu screen is displayed. English 23 01_EN_EM19A026_IM.
Field Setting Field settings method This section describes how to perform field setting. Refer to page 23 and enter the installer menu. Installer menu screen Field Setting Text mode Icon mode Press or button, for move to “ ”. If Bluetooth is connected, performing field setting from the remote controller side is impossible. Disconnect Bluetooth, or perform field setting from the mobile application.
Sub-menu screen Mode 20 Unit 00 Enter Return Mode 20 Unit 00 Text mode Icon mode Press or button, scroll to the desired Unit No. and then press button to set the selection. Sub-menu screen Mode 20 Unit 00 Enter Return Mode 20 Unit 00 Text mode Icon mode Press or button, to select “Enter” or “ ”, and then press button to set the selection. Sub-menu screen a b SW 00 – 01 Set Cancel Text mode SW 00 – 01 Press or button, select First Code No., and then press button. a First Code No.
Sub-menu screen SW 00 – 01 Set Cancel SW 00 – 01 Text mode Press or button, to scroll to the desired Second Code No., and then press button. Icon mode Sub-menu screen SW 00 – 01 Set Cancel SW 00 – 01 Text mode Icon mode Press or button, select “Set” or “ ”, and then press button to save the setting and return to the previous screen. If the setting is not changed, select “Cancel” or “ ”.
NOTICE • Installation of optional accessories on the indoor unit may require changes to field settings. See the manual of the optional accessory. • For field setting details related to the indoor unit, see installation manual shipped with the indoor unit. Field setting mode list Mode First No. Code (Note 1) No. 2 10 (20) 5 12 (22) 2 1C 01 1E 02 Second Code No.
R/C Setting R/C setting method This section describes how to perform R/C setting. Refer to page 23 and enter the installer menu. Installer menu screen R/C Setting Text mode Icon mode Press or button, move to “ ”. If Bluetooth is connected, performing field setting from the remote controller side is impossible. Disconnect Bluetooth, or perform field setting from the mobile application. Sub-menu screen a b Mode R1 Unit – – Enter Return Text mode Mode R1 Unit – – Press or button, to select Mode No.
Sub-menu screen a b SW 03 – 00 Set Cancel Text mode SW 03 – 00 Press or button, select First Code No., and then press button. a First Code No. b Second Code No. Icon mode Sub-menu screen SW 13 – 00 Set Cancel SW 13 – 00 Text mode Press or button, scroll to the desired First code No. and then press button to set the selection. Icon mode Sub-menu screen SW 13 – 00 Set Cancel SW 13 – 00 Text mode Press or button, to move Second Code No., and then press button.
Sub-menu screen SW 13 – 00 Set Cancel SW 13 – 00 Text mode Icon mode Press or button, select “Set” or “ ”, and then press button to save the setting and return to the previous screen. If the setting is not changed, select “Cancel” or “ ”. Sub-menu screen Mode R3 Unit – – Enter Return Mode R3 Unit – – Text mode Icon mode or button, move to “Return” or Press “ ”, and then press button to return to the installer menu.
R/C setting mode list Mode No. First Code No. R1 07 R1 11 R1 12 R3 00 R3 01 R3 02 R3 03 R3 04 R3 05 R3 06 R3 07 R3 08 R3 09 R3 10 R3 11 R3 13 Second Code No.
Installer Password Setting Installer password setting method This section describes how to perform password setting. Refer to page 23 and enter the installer menu. Installer menu screen Installer Password Text mode Icon mode Press or button, for move to “ ”. If Bluetooth is connected, performing field setting from the remote controller side is impossible. Disconnect Bluetooth, or perform field setting from the mobile application.
Sub-menu screen Enable 0 0 0 0 Set Cancel 0 0 0 0 Text mode Icon mode Press or button, set any password, and then press button. Each time button is pressed, the digit place will change. When the 4th digit on the right end is reached, press button to return to the previous screen. Sub-menu screen Enable 1 2 3 4 Set Cancel 1 2 3 4 Text mode Icon mode Press or button, select “Set” or “ ”, and then press button to return to the installer menu.
Certification COMPLIANCE WITH FCC RULES AND REGULATIONS 15.21 You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment. 15.105(b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
License The following OSS is included in the remote controller. [micro-ecc] Copyright (c) 2014, Kenneth MacKay All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: * Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
EM19A026 01_EN_EM19A026_IM.