CTXS07LVJU Owners Manual

28
English
Note for Multi System
NOTE
Notes on operation mode for multi system
COOL, DRY and FAN operation may be used at the same time.
AUTO operation automatically selects COOL operation or HEAT operation based on the room temperature.
Therefore, AUTO operation is available when selecting the same operation mode as that of the room with the rst unit to be turned on.
CAUTION
Normally, the operation mode in the room where the unit is rst run is given priority, but the following situations are exceptions, so please keep this
in mind.
If the operation mode of the rst room is FAN operation, then using HEAT operation in any room after this will give priority to HEAT operation. In
this situation, the air conditioner running in FAN operation will go on standby, and the OPERATION lamp will ash.
With the priority room setting active.
Refer to “Priority room setting” on the next page.
NIGHT QUIET mode (Available only for COOL operation)
NIGHT QUIET mode requires initial programming during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET mode reduces the operation noise of the outdoor unit during the nighttime hours to prevent annoyance to
neighbors.
The NIGHT QUIET mode is activated when the temperature drops 10.8°F (6°C) or more below the highest temperature recorded that day.
Therefore, when the temperature difference is less than 7.2°F (4°C), this function will not be activated.
NIGHT QUIET mode reduces slightly the cooling ef ciency of the unit.
OUTDOOR UNIT QUIET operation
Refer to “OUTDOOR UNIT QUIET operation”.
Page 18
With the priority room setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor units to OUTDOOR UNIT
QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.
With the priority room setting active.
Refer to “Priority room setting” on the next page.
Multi system has one outdoor unit connected to multiple indoor units.
Selecting the operation mode
With the priority room setting present but
inactive or not present.
When more than one indoor unit is operating, priority is given to the
rst unit that was turned on.
In this case, set the units that are turned on later to the same operation
mode as the rst unit.
Otherwise, they will enter the standby state, and the OPERATION
lamp will ash: this does not indicate malfunction.
A room B room
C room D room
Outdoor unit
01_EN_3P297290-1.indd 2801_EN_3P297290-1.indd 28 10/21/2011 6:28:47 PM10/21/2011 6:28:47 PM