Specifications

Outdoor Unit SiBE04-624
280 Removal Procedure
2.7 Removal of the Electrical Box
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1. Disconnect the wire
harnesses of the PCB
Preparation
Remove the front panel
according to "Removal of
Propeller Fan / Fan Motor".
1
Detach the harnesses
for humidify unit from
the hook.
2
Disconnect the
connector for fan motor
[S70] from the PCB.
3
Disconnect the
connector for
humidifying fan motor
[S72].
4
Disconnect the
connector for four way
valve coil [S80].