Specifications

Others SiBE04-624
300 Others
1.2.2 How to set the different addresses
When 2 indoor units are installed in one room, the 2 wireless remote controllers can be set for
different addresses.
1.2.3 Jumper Setting
1) Remove the front grille. (3 screws)
2) Cut the address jumper “JA”.
(See Fig. 1)
3) Remove the remote controller lid and
cut the address jumper “J4”.
(See Fig. 2)
Electric parts box cover
Cut JA.
Fig. 1
J4
Fig. 2
Cut section
(R5989)
Jumper
(On indoor control PCB)
Function When connected
(factory set)
When cut
JC Power failure
recovery function
Auto-restart Unit does not resume operation
after recovering from a power
failure. Timer ON-OFF settings
are cleared.
JB Fan speed setting
when compressor is
OFF on thermostat.
(effective only at
cooling operation)
Fan speed setting ;
Remote controller
setting
Fan rpm is set to “0”
<Fan stop>