Operation manual Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA Operation manual Daikin Altherma hybrid heat pump English
Table of contents Documentation set Table of contents This document is part of a documentation set. The complete set consists of: 1 About this document 2 2 About the system 2 2.1 Components in a typical system layout ..................................... 3 Operation 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Overview: Operation.................................................................. The user interface at a glance ................................................... 3.2.1 Buttons......................
Operation C a b c d e f g Technical room. Example: Garage. Outdoor unit heat pump Indoor unit heat pump Instant domestic hot water or domestic hot water (DHW) tank User interface at the indoor unit User interface in the living room, used as room thermostat Radiators Heat pump convectors or fan coil units Operation 3.1 Overview: Operation f You can operate the system via the user interface.
3 Operation Icon 3.3.2 Description Holiday mode is active or ready to be activated. Child lock mode and/or function lock mode is active. Boiler operation. Using the room temperature home page Typical room temperature home pages Depending on the user profile, the user interface gives you either a basic or a detailed home page. To switch between home pages, go to [7.1.3]: > User settings > Display > User profile. Heat pump (compressor) operation.
3 Operation 3.4 Example: Domestic hot water control Tt 3.4.1 1 2 Instant DHW (no tank installed) When there is a demand for hot water tapping, the boiler provides DHW instantly. The DHW temperature is visible on the boiler's main display. Using the instant DHW home page 60°C 50°C 40°C User profile = Detailed Tue 01:03 DHW Tue 01:03 DHW 44°C 44°C Desired temperature To adjust the instant DHW temperature Go to the instant DHW home page.
3 Operation To save the schedule To read out and adjust the desired reheat temperature (in scheduled and reheat mode) 1 2 1 Press Go to [7.4.3.3]: > User settings > Preset values > Tank temperature > Reheat. 2 Select User defined 1, User defined 2 or User defined 3 and press . Result: You can read out the desired reheat temperature. 3 Change the name and press . (Only applicable for room temperature schedules). Example: MyWeekSchedule Press or to adjust.
3 Operation 3.
4 Setting the energy prices 3.7 Installer settings: Tables to be filled in by installer Setting Default Fuel price 3.7.1 Quick wizard 3.7.3 Setting Default Domestic hot water control [A.4] Setting 0 (No) Space heating/cooling settings [A.2.
5 Energy visualisation 4.3 To set the electricity price schedule timer 1 Go to [7.3.8]: 2 Program the schedule according to the High, Medium and Low electricity prices for each time interval. > User settings > Set schedules > Elec price. 3 Press to save the schedule. INFORMATION The values for High, Medium and Low correspond with the electricity price values for High, Medium and Low previously set. If no schedule is set, the electricity price for High is taken into account.
8 Troubleshooting 8 8.1 Troubleshooting Symptom: You are feeling too cold (hot) in your living room Possible cause Corrective action The desired room temperature is Increase (decrease) the desired too low (high). room temperature. If the problem recurs daily, do one of the following: 8.3 Symptom: Heat pump failure When the heat pump fails to operate the gas boiler can serve as an emergency backup heater and either automatically or non automatically take over the entire heat load.
4P3495881B 2013.