3.4 Domestichotwatercontrol
3.4.1 InstantDHW(notankinstalled)
When there is a demand for hot watertapping, the boiler provides
DHWinstantly.TheDHWtemperatureisvisibleontheboiler'smain
display.
UsingtheinstantDHWhomepage
Dependingontheuserprofile,theuserinterfacegivesyoueithera
basicoradetailedhomepage.
Userprofile=Basic Userprofile=Detailed
01:03
Tue
DHW
Desired temperature
44°C
01:03
Tue
DHW
Desired temperature
44°C
ToadjusttheinstantDHWtemperature
1 GototheinstantDHWhomepage.
2 Press or toadjusttheinstantDHWtemperature(DHW).
TheinstantDHWsetpointtemperaturemayNOTbebelow40°C.
3.4.2 Tank
Thefollowingmodesareonlyapplicableifatankisinstalledandare
setbytheinstaller.
Reheatmode
In reheat mode ( ), the DHW tank continuously heats up to the
desiredtemperature(example:50°C).
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
T
t
T
t
:DHWtanktemperature
t:Time
INFORMATION
When the DHW tank booster mode is active, the risk of
space heating/cooling and capacity shortage comfort
problems is significant. In case of frequent domestic hot
water operation, frequent and long space heating/cooling
interruptionswillhappen.
Scheduledmode
In scheduled mode ( ), the DHW tank produces hot water
corresponding to a schedule. The best time to allow the tank to
producehotwaterisatnight,because:
Thespaceheatingdemandislower
Electricitytariffsarelower
Example:
t
60°C
00:00 07:00
50°C
15°C
40°C
14:00 21:00
1
2
3
4
5
T
t
T
t
:DHWtanktemperature
t:Time
Scheduled+reheatmode
Inscheduled+reheatmode( ),thedomestichotwatercontrolis
the same as in scheduled mode. However, when the DHW tank
temperaturedropsbelowapresetvalue(=Reheat;example:45°C),
the DHW tank heats up until it reaches this preset value. This
ensuresthataminimumamountofhotwaterisavailableatalltimes.
Example:
t
T
t
60°C
00:00 07:00
50°C
45°C
15°C
40°C
14:00 21:00
1
2
43
UsingtheDHWtanktemperaturehomepage
TypicalDHWtanktemperaturehomepages
Dependingontheuserprofile,theuserinterfacegivesyoueithera
basic or a detailed home page. Depending on an installer setting,
either anactualtemperatureora number of people is displayed to
indicatethedomestic hotwatertank temperature.Theexamples in
theillustrationsbelowareinDHWtankmode=Scheduled.
Userprofile=Basic Userprofile=Detailed
15:20
Mon
Tank
Desired temperature
60°C
15:20
Mon
Tank
Storage comfort
60°C
Tue 00:00
15:20
Mon
Tank
Desired temperature
4
15:20
Mon
Tank
Storage comfort
4