User manual

©2012DaikinACSlide20
PUBLIC CONFIDENTIAL
DRAFT
ConfiguringtheDaikinENVi Thermostat
SystemSettings
(continued)
AC Overcool Max When using the AC to dehumidify, the setting configures how
many degrees below the current set point the thermostat will run in order to reach
the dehumidify set point. Options are Disabled (default) and 0.5 to 3 °F (0.3 to 1.8°C)
in 0.5 F (0.3°C) increments.
Heat Differential Temp The minimum difference between the current temperature
and set temperature before the system calls for heat. A smaller difference means
shorter cycle times, whereas a larger difference results in longer cycle times. The
temperature range is adjustable form 0.5 to 3 °F (0.3 to 1.7 °C) in 0.5°F (0.3°C)
increments. The default offset is 0.5°F (0.3°C).
If the Indoor Unit is AC only and an auxiliary heater is configured, this option
appears under the Aux Heat Settings menu.
Heat Dissipation Time The amount of time the fan will run after the heat set point
has been reached and the call for heat has been turned off. Running the fan for a
period of time allows for heated air to circulate throughout the home. The time is
adjustable from 0 to 900 seconds (default is 0 seconds).
If the Indoor Unit is AC only and an auxiliary heater is configured, this option
appears under the Aux Heat Settings menu.