ConfiguringtheDaikinENVi Thermostat
Installation
Settings
Aux Heat Settings: Menu > Settings > Installation Settings > Aux Heat Settings
The Aux Heat Settings configure an auxiliary heat source.
If you want to test the auxiliary heater during installation, set Aux Heat Installed to
Yes and set Allow HP with Aux Heat to No. Then, adjust the heat set point to enable
the auxiliary heater.
Aux Heat Installed When set to Yes, configures the thermostat to control an
auxiliary heat source.
Aux Heat Requires Fan When set to Yes, configures the thermostat to control the
fan when auxiliary heat is used.
Allow HP with Aux Heat When set to Yes, it will turn on auxiliary heat in addition to
the heat pump. For information about how auxiliary heat will be engaged with the heat
pump, see the settings Heat Pump to Aux Temp Delta and Heat Pump to Aux
Runtime.
Aux Min On Time Sets the minimum equipment run time for auxiliary heat: 1 to 20
min (default is 5 min).
Max Outdoor Temp Configures the maximum outdoor temperature threshold.
Above this level, the auxiliary heat will not be activated. The temperature is adjustable
from 0 to 80 °F (26.5 °C) in increments of 0.5°F (0.5°C). The default value is 70°F
(21°C).