Specifications

Si04-306B Specifications
Specifications 23
230V, 50Hz
Notes:
MAX. interunit piping length: 30m
MIN. interunit piping length: 1.5m
MAX. interunit height difference: 20m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Model
Indoor Units ATXS50CVMB
Outdoor Units
ARXS50CVMB
Cooling Heating
Capacity
Rated (Min.~Max.)
kW 5.0 (0.9~5.8) 5.8 (0.9~7.5)
Btu/h 17,070 (3,070~19,800) 19,800 (3,070~25,610)
kcal/h 4,300 (770~4,990) 4,990 (770~6,450)
Moisture Removal L/h 2.9
Running Current (Rated) A 7.3 7.5
Power Consumption
Rated (Min.~Max.)
W 1,660 (450~2,300) 1,700 (450~2,580)
Power Factor % 98.9 98.6
COP W/W 3.01 3.41
Piping
Connections
Liquid mm
φ
6.4
Gas mm
φ
12.7
Drain mm
φ
18.0
Heat Insulation Both Liquid and Gas Pipes
Indoor Unit ATXS50CVMB
Front Panel Color White
Air Flow Rate
m³/min
(cfm)
H 11.4 (402) 12.6 (445)
M 9.7 (342) 10.8 (381)
L 8.0 (282) 8.9 (314)
SL 7.1 (251) 7.7 (272)
Fan
Type Cross Flow Fan
Motor Output W 40
Speed Steps 5 Steps, Silent and Auto
Air Direction Control Right, Left, Horizontal and Downward
Air Filter Removable / Washable / Mildew Proof
Running Current (Rated) A 0.18 0.20
Power Consumption (Rated) W 40 45
Power Factor % 96.6 97.8
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 290×795×238
Packaged Dimensions (H×W×D) mm 280×840×338
Weight kg 9
Gross Weight kg 13
Operation
Sound
H/M/L/SL dBA 44/40/35/32 42/38/33/30
Sound Power H dBA 63 60
Outdoor Unit ARXS50CVMB
Casing Color Ivory White
Compressor
Type Hermetically Sealed Swing Type
Model 2YC32HXD
Motor Output W 1,500
Refrigerant
Oil
Model FVC50K
Charge L 0.65
Refrigerant
Model R410A
Charge kg 1.20
Air Flow Rate m³/min (cfm)
H 47.7(1,684) 44.1(1,557)
L 44.1(1,557) 44.1(1,557)
Fan
Type Propeller
Motor Output W 53
Running Current (Rated) A 6.82 7.30
Power Consumption (Rated) W 1,620 1,655
Power Factor % 99.0 98.6
Starting Current A 7.5
Dimensions (H×W×D) mm 735×825×300
Packaged Dimensions (H×W×D) mm 784×960×390
Weight kg 49
Gross Weight kg 53
Operation
Sound
H dBA 47 48
Sound Power H dBA 63 64
Drawing No. 3D044869
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling Heating Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB/24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB/6°CWB
7.5m