Operation Manual
12
■
To change the temperature setting
Press .
• The displayed items on the LCD will change whenever either one of the buttons is
pressed.
COOL operation HEAT operation AUTO operation DRY or FAN operation
18–32°C 10–30°C 18–30°C
The temperature setting is
not variable.
Press
to raise the temperature and press to lower the
temperature.
■
Operating conditions
■
Recommended temperature setting
• For cooling: 26–28°C
• For heating: 20–24°C
■
Tips for saving energy
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air lters cause inefcient operation and waste energy. Clean them once in about every 2 weeks.
■
Notes on the operating conditions
• The outdoor unit consumes some power to have its electric components work even while it is not operating.
Connecting outdoor unit RXS20/25: 1–15W
Other outdoor units: 15–20W
The outdoor unit consumes 40 to 55W of power at the time of compressor preheating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker off.
• Use the air conditioner in the following conditions.
• Operation outside the humidity or temperature range described in the table may cause a safety device to disable the system.
MODE Operating conditions If operation is continued out of this range
COOL
Outdoor temperature : <2MXS> 10–46°C
<3/4/5MXS> -10–46°C
<RXS> -10–46°C
Indoor temperature : 18–32°C
Indoor humidity : 80% max.
• A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the
outdoor unit only.)
• Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature : <2/3/4/5MXS> -15–24°C
<RXS> -15–24°C
Indoor temperature : 10–30°C
• A safety device may work to stop the operation.
DRY
Outdoor temperature : <2MXS> 10–46°C
<3/4/5MXS> -10–46°C
<RXS> -10–46°C
Indoor temperature : 18–32°C
Indoor humidity : 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.