Operation Manual
41
Problemen oplossen
■
LED OP DE PCB VAN DE BUITENUNIT
3MXS, 4MXS, 5MXS serie
GROEN ROOD
MICROCOMPUTER
NORMAAL
STORING OPGETREDEN
LED-A LED1 LED2 LED3 LED4 LED5 DIAGNOSE
●●●●●
NORMAAL CONTROLEER BINNENUNIT
● ●
OVERDRUKBEVEILIGING OF BEVRIEZINGSBEVEILIGING
INGESCHAKELD BIJ APPARAAT IN WERKING OF IN STAND-BY
●
●
●
* OVERBELASTINGSRELAIS INGESCHAKELD OF HOGE
TEMPERATUUR AFVOERLEIDINGE
●
●
●
STARTMECHANISME COMPRESSOR DEFECT
● ● ●
OVERSPANNING OP INGANG
●●●
* STORING THERMISTOR OF CT
● ●
HOGE TEMPERATUUR IN AANSLUITINGENCOMPARTIMENT
●●● ●
HOGE TEMPERATUUR IN STROOMOMZETTERCIRCUIT VAN
KOELPLAAT
●● ●●
* OVERSPANNING OP UITGANG
●● ●
* ONVOLDOENDE KOELMIDDEL
●● ●
LAGE SPANNING NAAR HOOFDCIRCUIT OF TIJDELIJKE
WERKSPANNINGSONDERBREKING
●●●●
OMKEERMAGNEETKLEP DEFECT
●
VENTILATORMOTOR DEFECT
−−−−
●
[OPMERKING 1]
●
−−−−
●
VOEDINGFOUT OF [OPMERKING 2]
OPMERKING: LED5 werkt alleen bij modellen uit de 5M-serie.
GROEN KNIPPERT NORMAAL
ROOD
GEWOONLIJK UIT
AAN
KNIPPERT
●
UIT
−
NIET RELEVANT
■
LED OP DE PCB VAN DE BUITENUNIT
2MXS serie
GROEN
MICROCOMPUTER NORMAAL
LED-A DIAGNOSE
NORMAAL CONTROLEER BINNENUNIT
[OPMERKING 1]
●
VOEDINGFOUT OF [OPMERKING 2]
GROEN KNIPPERT NORMAAL
AAN
KNIPPERT
●
UIT
OPMERKING
•Schakel de spanning uit en dan weer in. Als de LED display opnieuw verschijnt, is de printplaat van de buitenunit defect.
•Diagnose gemarkeerd
* Zijn in sommige gevallen niet van toepassing. Zie de onderhoudsgids voor meer bijzonderheden.