For BPMK928B42 ยท 43 SiE18-201
264 Removal Procedure
2. Removing the PCB ๎€‚ The PCB is treated for
moisture resistance.
Replace the PCB and its
mount together, if required.
๎€‚ The LED (green) lights up
while the microcomputer
functions.
๎€‚ Self-diagnostic LEDs
LED-A (green)
LED-1 (red)
LED-2 (red)
LED-3 (red)
LED-4 (red)
S4: Motorized valve coil (yellow)
S3: Motorized valve coil (blue)
S2: Motorized valve coil (red)
S1: Motorized valve coil (white)
1
The codes of the
connectors on the PCB
are as shown at right.
2
Remove the four
screws from the PCB.
3
Loosen the two
keyhole-provided
screws and remove the
two other screws from
the PCB mount.
Step Procedure Points
Earth wire
S7 S9 S5 S4
S3
S2
S1
Indoor-side
terminals
Earth
terminals
(indoor side)
Glass fuses, 3.15A
(M1118)
Outdoor-side
terminals
Earth terminal
(outdoor side)
Loosen these
keyhole-provided screws.
Wire harness
clamp screws
(M1120)