Engineering

EDUS181520C Options for BP Unit
Options 475
5
Installation
SELECTION PROCEDURE
φ28.6 φ22.2
φ22.2
INSULATION
φ15.9
S H A P E
φ22.2
GAS SIDE JOINT
φ25.4
φ6.4
REDUCER (FOR LIQUID PIPE)
φ22.2
LIQUID SIDE JOINT
φ19.1
φ25.4/φ22.2
φ19.1
φ19.1
REDUCER (FOR GAS PIPE)
φ38.1
φ22.2
φ31.8
φ28.6 2 PCS.
2 pcs.
2 pcs.
2 pcs.
2 pcs.
φ19.1
According to the INSTALLATION MANUAL of outdoor unit.
φ12.7
I.Dφ19.1
I.Dφ38.1
I.Dφ12.7
I.Dφ9.5
I.Dφ31.8
I.Dφ31.8
I.Dφ9.5
I.Dφ9.5
I.Dφ25.4
I.Dφ15.9
I.Dφ15.9
I.Dφ19.1
I.Dφ15.9
I.Dφ12.7
I.Dφ9.5
I.Dφ25.4
I.Dφ9.5
I.Dφ31.8
I.Dφ6.4
I.Dφ15.9
I.Dφ12.7
I.Dφ6.4
I.Dφ15.9
I.Dφ25.4
I.Dφ15.9
I.Dφ15.9
I.Dφ15.9
I.Dφ12.7
I.Dφ12.7
I.Dφ19.1
I.Dφ12.7
I.Dφ22.2
I.Dφ9.5
I.Dφ12.7
I.Dφ25.4
I.Dφ12.7
I.Dφ6.4
I.Dφ15.9
I.Dφ19.1
I.Dφ9.5
I.Dφ28.6
I.Dφ12.7
I.Dφ19.1
I.Dφ12.7
I.Dφ15.9
I.Dφ6.4
I.Dφ28.6
I.Dφ12.7
I.Dφ9.5
I.φD19.1
I.Dφ19.1
I.Dφ6.4
I.Dφ9.5
I.Dφ15.9
I.Dφ19.1
I.Dφ15.9
Inlet
Outlet
Inlet
INSTALLATION PROCEDURE
Outlet
Outlet
Inlet
GAS SIDE JOINT
Outlet
Inlet
Outlet
Inlet
Inlet
The pipe size of each parts are shown below.
KIT NAME
Outlet
LIQUID SIDE JOINT
Outlet
Outlet
Inlet
Inlet
THIS KIT INCLUDES THE FOLLOWING PARTS.
KIT NAME
KHRP26A
22T
KHRP26A
22T
KHRP26A
33T
KHRP26A
72T
KHRP26A
73T
KHRP26A
33T
KHRP26A
72T
KHRP26A
73T
Make sure gas side joint and liquid side joint are for R410A. (Label for R410A is attached on each part.)