SiENBE81-623A Air Purifiers MC707VM-S MC707VM-W 1.Introduction ......................................................................................................2 2.Precautions for Use..........................................................................................8 2.1 Required Conditions ............................................................................8 2.2 Applicable Room Area .........................................................................8 3.Specifications ............
Introduction SiENBE81-623A 1. Introduction Photocatalytic Air Purifier flash streamer 06CJG-2 Daikin's original electro-discharge streamer technology is used for powerful decomposition and removal efficiency in the flash streamer air purifiers we are marketing globally. Totally differentiated from the competition, our technology and performance are available nowhere else.
SiENBE81-623A Introduction NEW Daikin original Flash streamer discharge unit NEW Prefilter Bio-antibody (with filter catechin) Plasma ionizer NEW Streamer space NEW Titanium Electrostatic Streamer Apatite dust deodorizing Photocatalytic collection catalyst Filter filter 06CJG-5 Decomposition is continuous Formaldehyde concentration in room (ppm) When formaldehyde’s concentration of 0.
Introduction SiENBE81-623A Adjuvants are substances included in air pollutants such as exhaust gas that, when inhaled along with allergens, make one's allergy symptoms worsen. Allergy symptoms worsen. Adjuvant Allergens Adjuvant Mites Pollen Mold and others Diesel Diesel exhaust(DPE) exhaust(DPE) Diesel exhaust particles Exhaust gas (NOx, formaldehyde, etc.) VOC (toluene,xylene, etc.) and others Allergens Pollen Only flash streamer removes adjuvants.
SiENBE81-623A Introduction NEW Bio-Antibody Filter The Bio-Antibody filter works in the same way as the influenza vaccination. It removes viruses in about 1 minute. • The Bio-Antibody filter is usable for one year after opening. • Replacement for subsequent years will be available. • Operation will not be adversely affected if the Bio-Antibody filter is not used. • Effective for 3 years from date of manufacture.
Introduction SiENBE81-623A Designed to be quiet A mere 31 dB even in M mode (standard mode). It's as quiet as a whisper. Top-ranking silent operation is achieved by Daikin's original shroud fan and a low-pressure-loss filter. Operation sound and air flow Operation sound (dB) Airflow (m3/h) Quiet Low noise 16 dB in LL mode 60 Noise level of 40 dB is that of a library.
SiENBE81-623A Introduction Flat panel blends with interiors and is easy to clean. Quick-wipe panel Designed for easy maintenance, a single wipe with a wet cloth is all it takes to keep it clean.
Precautions for Use SiENBE81-623A 2. Precautions for Use 2.1 Required Conditions !Ambient Temperature/Humidity Use this product under the following conditions. Operating conditions Room temperature 0°C - 32°C Room humidity 80% or less Use under other conditions may cause malfunction. !Miscellaneous •This product is for home use. Do not use for special purpose. •This product is for indoor use only. Do not use in bathroom or outdoors as it is not water/condensation proof. •Do not modify this product.
SiENBE81-623A Specifications 3. Specifications 3.1 Specifications Model MC707VM-S Type MC707VM-W Photocatalytic air purifier 1φ 220-240 / 220-230V 50 / 60Hz Power supply Sparkling silver + metallic ocean blue Color White + Sparkling silver Rated power consumption (HH/H/M/L/LL) W 55 / 23 / 14 / 10 / 8 Running current (HH/H/M/L/LL) A 0.48 / 0.22 / 0.14 / 0.10 / 0.
Specifications 3.2 SiENBE81-623A Dimensions · Required installation space Signal Transmitter 11 8 90 Air outlet grille 100.or more MC707VM-S, MC707VM-W 500. or more 1000.or more 500. or more 52 • Dimension of remote controller Air inlet grille 1000. or more (ARC437A3) Handles 533 Air inlet grille Manufacturer's Label 1 1.3 425 2 4 1.3 213 11 Power supply cord Approx. 2.
SiENBE81-623A 3.
Specifications 3.
SiENBE81-623A Operation Manual 4. Operation Manual 4.1 Safety Precautions Safety Precautions • Keep this manual where the operator can easily find them. • Read this manual attentively before starting up the unit. • For the reason of safety the operator must read the following cautions carefully. • Do not use outdoors or where exposed to direct sunlight. Direct sunlight can weaken remote control signal reception sensitivity and discolor the casing. • Do not use near to sources of heat such as heaters.
Operation Manual 4.2 SiENBE81-623A Names and Operation of each Part Names and Operation of each Part Main unit Front 6 4 8 Shock-absorbing material (cardboard) 13 12 3 5 Be sure to remove the shock-absorbing material before operating. (page 5.) 10 11 2 Pleated filter Rear 16 14 15 17 18 19 19 14 7 9 1 20 1 Front panel 14 Air inlet 2 Main unit display (page 4.) 15 Remote control storage slot Shows operation status.
SiENBE81-623A Operation Manual Main unit display 1 2 4 3 5 13 6 Air is taken in from here and the dust sensor detects the dirty state of the air. 2 Clean monitor (Dust) Detects the dirty state of the air and indicates the results. Indicator 8 9 10 11 12 14 4 Automatic operation indicator (yellow) 1 Air intake for dust sensor Dust 7 15 Off On Green Low Lit during automatic operation. 5 Airflow rate indicator (green) (page 7.) Lit by the set airflow rate setting.
Operation Manual 4.3 SiENBE81-623A Preparation before Operation Preparation Before Operation Remote control setup Remote control • Do not drop or place the remote control in water. 1. Remote control preparations (Damage may occur.) • Do not press the remote control buttons with sharp objects. • Battery is already set in the remote control but the remote control cannot be used as is without first preparing it. Use the remote control after pulling out the clear sheet from the battery cover.
SiENBE81-623A Operation Manual ! Attaching the bio-antibody filter 3. Attach the pleated filter. • Remove the pleated filter from the bag. The side with the three holes goes up 1. Remove the pre-filter. Pleated filter • Remove by pulling out in front while holding the tabs on top of the pre-filter. 1) Pull out in front to remove. 3) 3) 2) 4) 2) The white side should be facing you.
Operation Manual SiENBE81-623A 4 When you want to quickly clean the air Preparation Before Operation Press the “ ” [TURBO] button. • A high airflow rate will quickly remove any dirtiness in the air. • This is convenient to use when cleaning. 5 When you want to remove pollen ! Installation of main unit To install the unit, comply with the following standards to ensure performance. Press the “ ” [ANTI-POLLEN] button.
SiENBE81-623A 4.4 Operation Manual Care and Cleaning Care and Cleaning Cleaning chart Cleaning the air inlet for the dust/odor sensor For cleaning, remove each part in the number order. For restoring each part, follow the opposite order. • Clean dusts clogged in the air inlet for the dust/odor sensor. • Use crevice nozzle of a cleaner for cleaning. CAUTION • Stop operation and pull the power plug before cleaning.
Operation Manual SiENBE81-623A Care and Cleaning ! Cleaning the pre-filter NOTE It is recommended to clean the pre-filter every two weeks. • Securely close the panel. Failing to do so may cause activation of 1. Remove the front panel. the safety switch and out of unit operation. • Lay your finger to the dent at bottom of the main unit, hold bottom part of the panel and then pull it up. Front panel CAUTION • Do not dry at a location directly exposed to the sun.
SiENBE81-623A Operation Manual Replace a pleated filter (Replace the pleated filter when the “replace indicator” on the main unit display turns on or blinks.) 5) Insert the pleated filter into the left and right hooks. turn on 1. Remove the front panel. (page 9.) 2. Remove the plasma ionizer. Holding the handle, lift towards yourself and remove from the top 2 hooks. 4. Restore the plasma ionizer and the front panel. (page 6. 5. Insert the power plug. 6. Press the reset switch on the main unit display.
Operation Manual SiENBE81-623A Care and Cleaning 3. Remove the bio-antibody filter. Remove the bio-antibody filter from hooks (2 locations) at top of the plasma ionizer. Clean the plasma ionizer (If “cleaning sign” on the main unit display blinks) Top hooks (2 locations) Blink CAUTION Stop operation before cleaning and be careful not to cut your hands with the opposing pole plate or ionizer wires. (It is safer to use rubber gloves.) Bio-antibody filter 4. Remove the plasma ionizer.
SiENBE81-623A Operation Manual Contents Remove each part. 1) Ionizing frame 2) Ionized wire (page 11.) 3) Streamer discharger (page 11.) 4) Opposing pole plate (page 11.) Vacuum dusts on the surface with a cleaner. Vacuum Caution Do not remove the screws on the ionizer or streamer discharger. Breakdown may result. Soak in water or warm water with liquid mild detergent. (about 1 hour) Soak in water with detergent Clean off the dirt with a cloth or soft brush.
Operation Manual SiENBE81-623A Care and Cleaning CAUTION When cleaning the unit, be careful not to cut your hands with the opposing pole plate or ionizer wires. (It is safer to use rubber gloves.) When cleaning the unit, be careful not to cut the ionizer wires. Be sure to do in a shower-proof place such as bathroom or sink in a kitchen. Use only specified volume of liquid mild detergent. Do not use powder detergent or alkaline detergent and scrub with hard sponge.
SiENBE81-623A Operation Manual Assembling the plasma ionizer 2. Attach the streamer discharger. 1. Attach the opposing pole plates. 1) Securely insert the opposing pole plate into the hooks (2 locations in the middle) of the plasma ionizer. 1) Insert bottom of the streamer discharger to the ionizer frame. Insert downward 2) Attach the opposing pole plate while opening the knobs (one at a side) of the plasma ionizer. 2) Insert top of the streamer discharger. Open 3) Insert securely until it clicks.
Operation Manual SiENBE81-623A Care and Cleaning Cleaning the deodorization catalytic unit Vacuum dusts with a cleaner without removing from the main unit. (Do not wash.) NOTE If the operation of 4. is not performed, the unit will not return to normal operation mode. If the operation of 4. is performed, during the settings, the settings will not be correct. When the sensitivity is set high, it will become difficult for the sensor lamp to go out.
SiENBE81-623A 4.5 Operation Manual Troubleshooting Frequently asked questions Question 1. The dust sensor does not change from the red (green) lamp. 2. The sensitivity of the dust sensor seems to be bad (or too good). 3. Can I wash the deodorization catalytic unit? Is replacement necessary? 4. What to do if the ionizer wires are cut? 5. Is not a problem to use while the cleaning sign is blinking? Answer This is due to dusts built up in the dust sensor.
Optional Accessories SiENBE81-623A 5. Optional Accessories 5.1 Dimensions 5.1.1 Pleated Photocatalytic Filter KAC972A4E Specifications Model Item Material No. of packages KAC972A4E Non-woven fabric (electrostatic) (Antibacterial and antiviral agent impregnated) 7 Notes: 1. Replacement guideline: Every year (for about 7 years in total) 2. Appearance color: White (front), blue (back) 338 100 12 130 260 C:3JHB10512 5.1.2 Bio-Antibody Filter KAF972A4E Specifications Model Item Material No.
SiENBE81-623A Troubleshooting 6. Troubleshooting 6.1 Basic Inspection Good bye! (1) Is the connector for the PCB plugged in? Or is there any poor connection? Where are you going? Connect firmly! Broken! Pulle d ou t! (2) Is the wire harness broken? !It is not malfunction Red lamp is blinking. Time for cleaning the plasma ionizer. Red lamp is on or blinking. Replace the pleated filter and press the reset button.
Troubleshooting 6.2 SiENBE81-623A Troubleshooting 6.2.1 Equipment does not operate, or operation lamps does not light. Caution 1 Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Models Covered 5 Troubleshooting Diagnosis MC707VM-S MC707VM-W Is AC cord plugged in? Or is breaker "ON"? 2 Plug in AC cord. Set breaker to “ON”. No Yes Method of Malfunction Detection Close the panel firmly.
SiENBE81-623A Troubleshooting 6.2.2 Remote control sends signals erratically. Caution 1 Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Models Covered MC707VM-S MC707VM-W 5 Troubleshooting Diagnosis *Release child lock. Is battery correct? (2.5V or more?) 2 Method of Malfunction Detection Replace battery. No Replace remote control. No Replace display PCB. Check remote control for normal operation.
Troubleshooting SiENBE81-623A 6.2.3 Sensor LED remains lit. Caution 1 Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Models Covered MC707VM-S MC707VM-W 5 Troubleshooting Diagnosis Remedy Put the plug in a socket while pressing the ON/OFF switch. 2 3 Method of Malfunction Detection Does LED light out for about 5 seconds? Yes No It is not malfunction. The sensor is detecting dust in the air.
SiENBE81-623A Troubleshooting 6.2.4 DC fan locks. Caution 1 Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Models Covered MC707VM-S MC707VM-W 5 Troubleshooting Diagnosis Remedy Four airflow rate indicators blink simultaneously. 2 Method of Malfunction Detection Abnormality of the fan motor is detected by revolutions with the Hall IC while the fan motor is running. Retry to operate with ON/OFF switch.
Troubleshooting SiENBE81-623A 6.2.5 LED automatically operates. Caution 1 Be sure to turn off power switch before connect or disconnect connector, or parts damage may be occurred. Models Covered MC707VM-S MC707VM-W 5 Troubleshooting Diagnosis Remedy *Entering demo mode Keep holding down reset switch and turn on power. LED may be in demo mode. Exit demo mode. 2 Method of Malfunction Detection Unplug unit or turn off power. Restart. Does unit beep after 3 seconds? No Demo mode is exited.
SiENBE81-623A Removal Procedure 7. Removal Procedure 7.1 Removal of the Front Panel / Filters Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points 1. Appearance Rear topside ON/OFF button Dust sensor * The upper part of the panel is roundish. When assembling, slide the panel in upright position for easy installation. 2. Removing the front panel (1) Hold both sides of the front panel and pull out the panel toward yourself.
Removal Procedure SiENBE81-623A Procedure Points * The projection at the back side of the front panel operates the safety switch. Be careful not to transform the projection. (2) Lift the panel to undo the hooks. Now detach the panel. Projection (backside) Knobs 3. Removing the prefilter (1) Bend the pre-filter slightly and detach the two upper knobs. Hooks Hooks Pre-filter * When assembling, catch the lower hooks first and then the right and left hooks.
SiENBE81-623A Removal Procedure Procedure Points Hooks 4. Removing the BioAntibody Filter (1) Bend the fixing part slightly to undo upper two hooks. * When assembling, catch the bottom hooks. (Unless the hooks are caught, the pre-filter, which uses the same hooks, cannot be assembled.
Removal Procedure SiENBE81-623A Procedure Points 5. Removing the plasma ionizer unit (1) Hold the grips of the plasma ionizer unit. Pull the unit toward yourself to release its bottom. Plasma ionizer unit (2) Lift the unit to undo the hooks. Now detach the unit.
SiENBE81-623A Removal Procedure Procedure Points 6. Removing the pleated filter (1) Undo the three hooks. Pleated filter (2) The filter is made of fiber. Undo the hook with stretching the filter. Hooks (3) Zoomed up view of the upper hooks.
Removal Procedure SiENBE81-623A Procedure Points (4) Undo the two bottom hooks and remove the filter. Hooks * When assembling, stick the Velcro. (5) A piece of Velcro is at the bottom. Velcro (6) Zoomed up view of the bottom hooks.
SiENBE81-623A Removal Procedure Procedure Points (7) Take out the spare filter from the holder. Pleated filter holder (8) Take out the filter from the bag and attach it.
Removal Procedure SiENBE81-623A Procedure Points 7. Removing the deodorizing catalytic filter (1) Undo the right and left hooks. (2) Undo the bottom hook and remove the deodrizing catalytic unit.
SiENBE81-623A Removal Procedure Procedure Points (3) Undo the two hooks at the bottom and remove the deodorizing catalytic filter. (4) When assembling, catch the bottom hooks, slightly bend the filter itself and fit it into position.
Removal Procedure 7.2 SiENBE81-623A Removal of Streamer Electric Discharge Unit Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure (1) Catch the upper hole with your finger and lift it up. Points Preparation in advance Streamer electric discharge unit * Remove the plasma ionizer unit. Part A Plasma ionizer unit. Part B (2) Zoomed up view of part A. (3) Zoomed up view of part B.
SiENBE81-623A Removal Procedure Procedure Points (4) Remove the screw. (5) Lift up and slide the unit to remove it. Photocatalytic Air Purifiers * When assembling, insert the upper narrow sheet metal.
Removal Procedure 7.3 SiENBE81-623A Removal of lonizing Wire Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points Part A 1. Removing the counter grid (1) Undo the outer hook and lift the counter grid to detach. (2) Zoomed up view of part A. Counter grid Hook Hook * When assembling, fit the position in the groove.
SiENBE81-623A Removal Procedure Procedure Points Hook 2. Removing the ionizing wires CAUTION Be careful not to get your hands cut by the ionizing wires. (1) Pinch and detach the ionizing wires with pincers. * Once removed, the ionizing wires cannot be reused. * When cleaning the ionizing wires, do not remove them. (See the Operation Manual.) * If the air purifier is used with the wire cut, the clean indicator will blink after 24 hours.
Removal Procedure 7.4 SiENBE81-623A Removal of Fan Motor Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points 1. Removing the back cover * Point Note that the screws are provided deep at the front. (1) Remove the 2 screws from the front top. (2) Remove the 2 screws from the back cover. (3) Lift and detach the back cover from the main body.
SiENBE81-623A Removal Procedure Procedure Points 2. Removing the fan motor (1) The figure shows the wiring routes. (2) Peel the seal material. Seal material * Once removed, the seal material cannot be reused. (3) Disconnect the fan motor connectors.
Removal Procedure SiENBE81-623A Procedure Points (4) Remove the nut and pull out the fan. * When assembling, align the mark on the fan with the D cut on the motor shaft. Fan D cut (5) Lift and detach the harness retainer. (6) When assembling, put part A first in the groove, and then slide part B along the way.
SiENBE81-623A Removal Procedure Procedure (7) Remove the 3 screws from the lock plate and take out the fan motor. Points Lock plate * The motor and the harness are integrated together. * Make sure no washers are left behind the fan.
Removal Procedure 7.5 SiENBE81-623A Removal of Electrical Box / PCB Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work. Procedure Points * Remove the back cover. * Disconnect the fan motor connector. 1. Disconnecting the faston terminal (1) Disconnect the terminal located at left. (2) Disconnect the terminal located at right. 2. Removing the electrical box (1) Remove the 2 screws from the front bottom. 52 * The screws are M4×12 in size.
SiENBE81-623A Removal Procedure Procedure Points * When assembling, fit the box in the groove. (2) Pull out the electrical box to detach. 3. Removing the PCB (1) Undo the 2 hooks at the back and take out the flame-proof plate. Flame-proof plate Photocatalytic Air Purifiers * When fitting the flameproof plate in position, be careful not to confuse the inserting positions.
Removal Procedure SiENBE81-623A Procedure (2) Disconnect the each connector. S8 Points S129 S35 S1 (3) Disconnect the connector S127 from the connector S128 of display PCB (A3P).
SiENBE81-623A Removal Procedure Procedure (4) Disconnect the PCB connector. Points * When connecting, connect firmly not to be unfastened. (5) Undo the 2 hooks and remove the PCB.
Removal Procedure SiENBE81-623A Procedure (6) The figure at right shows the power supply and control PCB. Points * Lead-free solder PbF is used. S1 S35 S129 S127 Fuse AC250V 3.15A S8 (7) Undo the 4 hooks to remove the high voltage PCB (HVU).
SiENBE81-623A Removal Procedure Procedure Points (8) Remove the tape. (9) Undo the 3 hooks from the back to remove the display PCB.
Removal Procedure SiENBE81-623A Procedure Points (10) Undo the 2 hooks (1 each at right and left) from the top. (11) Undo the 3 hooks to remove the PCB.
SiENBE81-623A Removal Procedure Procedure Points (12) Undo the hook from the dust sensor and push out the sensor from front. Dust sensor (13) Pinch the bulge of the safety door switch from inside to push out the switch.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment. "The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge.