Service manual
SiBE811120 Removal Procedure
Photocatalytic Air Purifier L-Series 51
2
The figure shows the
wiring of the wire
harness.
3
Disconnect the
connector for the fan
motor [S2].
4
Unscrew the nut and
pull out the fan.
When reassembling, align
the mark on the fan with
the D cut on the motor shaft.
Nut size: M8
Step Procedure Points
(R12368)
(R12369)
[S2]
Nut
Fan
Washer
(R14729)
D Cut
(R7768)
13 mm