Service manual

SiBE811120 Removal Procedure
Photocatalytic Air Purifier L-Series 57
4
Holding the convex
section and remove the
safety switch ASSY.
5
Disconnect the
connectors 1 and 3.
As a service part, a safety
switch ASSY has lead wires
on 2 and 4.
Step Procedure Points
(R14658)
Safety switch ASSY
(R10267)
(R12388)
(R14732)
1: Blue
Brown
4
2
3: White
Blue
(R10261)
3
4
21