Specifications
Troubleshooting SiBE81-909
58 Humidifying Air Purifier
7.4.2 The water supply lamp blinks.
1
Models Covered
5
Troubleshooting
MCK75JVM-K
Diagnosis Remedy
Set the humidifying
tray.
Replace the humid-
ifying tray
.
Connect the limit
switch connector.
[S115]
Replace the har-
ness.
Replace the limit
switch.
[S2C]
2
Method of Mal-
function Detection
3
Malfunction Deci-
sion conditions
4
Supposed Causes
•
The humidifying tray is removed or
not installed.
•
The humidifying tray is deformed
or broken.
•
The connector is improperly con-
nected.
•
The limit switch harness is broken.
•
The limit switch is defective.
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Is the humidifying
tray removed?
Is the protrusion at
left end of the humidifying
tray damaged?
Remove the front panel and
the water tank, and then
remove the humidifying tray.
Ye s
Ye s
No
Ye s
No
Is the harness broken?
Ye s
Is the limit switch
connector connected to the
power supply PCB?
No
No
Protrusion