7.5 Check
7.5.1 Checking the connection when the PCB is replaced.
Check1
Perform the following checking procedure when replacing the PCB.
(1)
Procedure
Pressing [ON/OFF] button and [Humidify ON/OFF] button simultaneously,
turn on the power. The buzzer sounds and all lamps light.
After checking the buzzer sound, press [ON/OFF] button once.
Press [Humidify ON/OFF] button once.
Use the 4 lamps for checking.
Press [Fan setting] button once.Check the sensor.
Reset the power supply to resume the normal mode.
The lamps corresponding to the PCB version light.
(2)
Procedure (Wiring check mode)
Insert the power supply plug into the outlet.
Press [OFF TIMER] button within 2 seconds.
Reset the power supply to resume the normal mode.
When the unit 1 lamp lights: The wiring of the dust correction HVU is improperly connected.
When the unit 2 lamp lights: The wiring of the streamer HVU is improperly connected.
When the unit 1 and unit 2 lamps light simultaneously: The wirings of the dust correction HVU
and the streamer HVU are improperly connected.
Normal
The buzzer sounds and all lamps light.
Refer to the 4 lamps below.
Error
Normal
The buzzer sounds and all lamps light.
(when connection is improper):
Error
When the unit 1 lamp blinks:
When the unit 2 lamp blinks:
The dust sensor is at fault or
improperly connected.
The odor sensor is at fault.
When the humidifying filter lamp blinks:
The humidifying sensor is at fault or
improperly connected.
When the air-purifying filter lamp blinks:
The room temperature thermistor is
at fault or improperly connected.