Specifications
Option List SiUS39-602
234 Appendix
4. Option List
4.1 Option List of Controllers
Optional Accessories of Operation Control System
C:3D043022D
Notes:
1.Installation box (No.4) is necessary for each adaptor marked
★
.
2.Electrical box (5-1/6-1) is required for controller (No. 5/6).
Building management system
Note:
★
1.BACnet
®
is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
★
2.L
ON
W
ORKS
is a registered trade mark of Echelon Corporation.
No.
Type
FXFQ~MVJU FXSQ~MVJU
FXMQ~MVJU FXAQ~MVJU
FXLQ~MVJU
FXNQ~MVJU
FXHQ~MVJU FXDQ~MVJU
Item
1 Remote controller
Wireless
BRC7C812 BRC4C82
BRC7E818
—
BRC7E83 BRC4C82
Wired
BRC1C71
BRC1D71
2 Set back time clock
BRC15A71
3 Remote sensor
KRCS01-1
4 Installation box for adaptor PCB
KRP1B98 — KRP1C93
KRP1B101
5 Central remote controller
DCS302C71
5-1 Electrical box
KJB311A
6 Unified on/off controller
DCS301C71
6-1 Electrical box
KJB212A
7 Schedule timer
DST301B61
8 External control adaptor for outdoor unit
★
DTA104A62
DTA104A61 — DTA104A61
★
DTA104A62
★DTA104A53
9 D3-NET Expander adaptor
DTA109A51
10 Simplified remote controller
—
BRC2A71
—
BRC2A71
—
BRC2A71
11 Adaptor for wiring
★KRP1B72 KRP1B71 ★KRP1B73
—
12 Wiring adaptor for electrical appendices (2)
★KRP4A73 KRP4A71 ★KRP4A72 ★KRP4A74
Part name Model No. Function
intelligent Touch
Controller
basic Hardware
intelligent
Touch
Controller
DCS601C71 • Air-Conditioning management system that can be controlled by a compact all-in-one unit.
Option Software Web DCS004A71
• Monitors and controls the air conditioning system using the Internet and Web browser
application on a PC.
Communication
Line
∗2 Interface for use in BACnet
®
DMS502A71
Interface unit to allow communications between VRV and BMS. Operation and monitoring of
air-conditioning systems through BACnet
®
communications.
Optional DIII board DAM411A1
Expansion kit, installed on DMS502A71, to provide 3 more DIII-NET communication ports. Not
usable independently.
Optional Di board DAM412A1
Expansion kit, installed on DMS502A71, to provide 16 more wattmeter pulse input points. Not
usable independently.
∗3 Interface for use in L
ON
W
ORKS
DMS504B71
Interface unit to allow communications between VRV and BMS. Operation and monitoring of
air-conditioning systems through L
ON
W
ORKS
communication.
Contact/Analog
signal
Unification adaptor for computerized
control
DCS302A72 Interface between the central monitoring board and central control units
Wiring adaptor for electrical
appendices (2)
KRP4A71-74
To control the group of indoor units collectively, which are connected by the transmission
wiring of remote controller.
External control adaptor for outdoor
unit (Must be installed on indoor
units.)
DTA104A53, 61,
62
Cooling/Heating mode change over. Demand control and Low noise control are available
between the plural outdoor units.