Service Diagnosis SiUS041638E
55 Service Diagnosis
Method 2
1. Press the center of Temp button and Mode button at the same time.
5C
is displayed on the LCD.
2. Select
5C
(service check) with Temp or Temp button.
3. Press Mode button to enter the service check mode.
The left-side number blinks.
4. Press Temp or Temp button and change the number until you hear the two consecutive
beeps or the long beep.
(R24533)
(R11821)
(R24534)
(R11670)
(R24535)