Dimensions EDUS181520C
34 Multi-Split Type Air Conditioners RMXS-L Series
FTXS15/18LVJU
FTXS24LVJU
DRAIN HOSE
(CONNECTING PART
O.D. φ5/8 (φ16mm)
THE HOSE LENGTH OF OUTSIDE
THE UNIT: ABOUT 18-5/16 (465mm))
SIGNAL
TRANSMITTER
11/16 (18mm)2-5/16 (58mm)
UP/DOWN
(AUTOMATIC)
FAN
COOLING, DRY
HEATING
15°
15°
25°
30°
7-3/8 (187mm)
25°
40°
75°
50°
60°
75°
70°
70°
WIRELESS REMOTE CONTROLLER
(ARC452A21)
41-5/16 (1050mm)
9-13/16 (250mm)
9-3/4 (248mm)
MIN.1-15/16 (50mm)
MIN.1-15/16 (50mm)
13-3/8 (340mm)
41-5/16 (1050mm)
9/16 (14.5mm)
1-3/8 (35.5mm)37-5/16 (947mm)
5/8 (16mm)
8-1/4 (210mm)
13-3/8 (340mm)
1-3/4 (45mm)
3-1/2 (89mm)2-9/16 (65mm)
1-3/4 (45mm)
45°
45°
THE MARK ( → )SHOWS PIPING DIRECTION
AIRFLOW (INDOOR)
REAR
LEFT
RIGHT
INCLUDING
INSTALLATION PLATE
(SPACE FOR
MAINTENANCE)
(SPACE FOR
MAINTENANCE)
REQUIRED SPACE
NAME PLATE
INTELLIGENT EYE SENSOR
BOTTOM
SIGNAL RECEIVER
FLAPS
OPERATION LAMP
TIMER LAMP
INTELLIGENT EYE LAMP
INDOOR UNIT ON/OFF
SWITCH
MODEL NAME PLATE
BLADE ANGLES
RIGHT/LEFT (AUTOMATIC)
MIN.1-3/16 (30mm)
(SPACE FOR
PERFORMANCE)
FRONT
GRILLE
FIXING
SCREWS
(INSIDE)
TERMINAL BLOCK
WITH
GROUND TERMINAL
(INSIDE)
GAS PIPE φ1/2 (φ12.7mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15-3/4 (400mm))
LIQUID PIPE φ1/4 (φ6.4mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 18-1/8 (460mm))
ROOM TEMP. THERMISTOR
(INSIDE)
WALL HOLE
φ3-1/8 (φ80mm) HOLE
WALL HOLE FOR EMBEDDED
PIPING φ3-1/8 (φ80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
( )
C: 3D074024A
SIGNAL
TRANSMITTER
2-5/16 (58mm) 11/16 (18mm)
UP/DOWN
(AUTOMATIC)
FANCOOLING, DRY HEATING
15˚ 15˚
25˚
30˚
7-3/8 (187mm)
25˚
40˚
75˚
50˚
60˚
75˚
70˚
70˚
41-5/16 (1050mm)
9-13/16 (250mm)
9-3/4 (248mm)
13-3/8 (340mm)
41-5/16 (1050mm)
9/16 (14.5mm)
1-3/8 (35.5mm)37-5/16 (947mm)
5/8 (16mm)
8-1/4 (210mm)
13-3/8 (340mm)
1-3/4 (45mm)
3-1/2 (89mm)2-9/16 (65mm)
1-3/4 (45mm)
45˚
45˚
THE MARK ( → ) SHOWS PIPING DIRECTION
AIRFLOW (INDOOR)
REAR
LEFT RIGHT
REQUIRED SPACE
NAME PLATE
INTELLIGENT EYE SENSOR
BOTTOM
SIGNAL RECEIVER
FLAPS
OPERATION LAMP
TIMER LAMP
INTELLIGENT EYE LAMP
INDOOR UNIT ON/OFF
SWITCH
MODEL NAME PLATE
BLADE ANGLES
RIGHT/LEFT (AUTOMATIC)
ROOM TEMP. THERMISTOR
(INSIDE)
WALL HOLE
φ3-1/8 (φ80mm) HOLE
WALL HOLE FOR EMBEDDED
PIPING φ3-1/8 (φ80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
FRONT
GRILLE
FIXING
SCREWS
(
INSIDE
)
WIRELESS REMOTE CONTROLLER
(
ARC452A21
)
DRAIN HOSE
(CONNECTING PART
O.D. φ5/8 (φ16mm)
THE HOSE LENGTH OF OUTSIDE
THE UNIT: ABOUT 18-5/16 (465mm))
GAS PIPE φ5/8 (φ15.9mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15-3/4 (400mm))
LIQUID PIPE φ1/4 (φ6.4mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 18-1/8 (460mm))
MIN. 1-15/16 (50mm)
(SPACE FOR
MAINTENANCE)
MIN. 1-15/16 (50mm)
(SPACE FOR
MAINTENANCE)
MIN. 1-3/16 (30mm)
(SPACE FOR
PERFORMANCE)
TERMINAL BLOCK WITH
GROUND TERMINAL
(
INSIDE
)
)(
INCLUDING
INSTALLATION PLATE
C: 3D073962A