Installation manual

27
English
NOTE
Operation with dirty lters:
cannot deodorize the air,1)
cannot clean the air,2)
results in poor heating or cooling,3)
may cause odor.4)
To order air-purifying lter with photocatalytic deodorizing function contact to the service shop there you purchased the air
conditioner.
Dispose of the old lters as ammable waste.
Item Part No.
Air-purifying lter with photocatalytic deodorizing function (without frame) 1 set KAF952A42
ATTENTION
Do not throw away the lter frame. Reuse the lter frame when replacing the air-purifying lter with photocatalytic deodorizing function.
CHECK
Check that the base, stand and other ttings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the
case.
Before a long idle period
Operate the FAN only for several hours on a nice day to dry out 1.
the inside.
Press and select “ ” operation.
Press
and start operation.
After operation stops, turn off the breaker for the room air 2.
conditioner.
Clean the air lters and set them again.
3.
Take out batteries from the remote controller.4.
01_EN_3P232717-3D.indd 2701_EN_3P232717-3D.indd 27 10/6/2009 9:21:22 AM10/6/2009 9:21:22 AM