Specifications
EDUS04-740 Capacity Tables
Room Air Conditioners D-Series 17
7. Capacity Tables
FTXS09DVJU + RX09FVJU (60Hz 208/230V)
Cooling
Heating
3D057579
INDOOR OUTDOOR TEMPERATURE(°FDB)
EWB EDB 68.0 77.0 86.0 89.6 95.0 104.0
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 8.67 5.68 0.71 8.27 5.46 0.76 7.88 5.24 0.81 7.72 5.14 0.83 7.48 5.01 0.86 7.08 4.79 0.92
60.8 71.6 9.13 5.87 0.71 8.73 5.65 0.76 8.33 5.43 0.81 8.18 5.34 0.83 7.94 5.21 0.86 7.54 4.99 0.91
64.4 77.0 9.52 6.02 0.70 9.13 5.81 0.75
8.73 5.59 0.80 8.57 5.52 0.83 8.33 5.38 0.86 7.93 5.16 0.91
67.0 80.0 9.72 6.10 0.70 9.32 5.89 0.75 8.92 5.67 0.80 8.77 5.58 0.82
8.50 5.44 0.85 8.13 5.24 0.91
71.6 86.0 10.31 6.33 0.70 9.91 6.12 0.75 9.51 5.91 0.80 9.35 5.82 0.82 9.12 5.69 0.85 8.72 5.48 0.90
75.289.610.706.460.6910.306.270.749.916.060.799.755.970.819.515.850.849.115.640.89
INDOOR OUTDOOR TEMPERATURE(°FWB)
EDB 14.0 23.0 32.0 43.0 50.0
°F TC PI TC PI TC PI TC PI TC PI
60.8 6.20 0.97 7.51 1.01 8.83 1.05 10.40 1.10 11.45 1.13
64.4 6.04 0.98 7.35 1.02 8.67 1.06 10.24 1.10 11.29 1.13
68.0 5.88 0.99 7.19 1.03 8.51 1.07 10.08 1.11 11.13 1.14
70.0 5.80 0.99 7.11 1.03 8.43 1.07
10.00 1.12 11.05 1.15
71.6 5.72 1.00 7.03 1.04 8.34 1.07 9.92 1.12 10.97 1.15
75.2 5.56 1.01 6.87 1.04 8.18 1.08 9.76 1.13 10.81 1.16
Symbols Note:
EWB : Entering wet bulb temp. (°F) 1. Ratings shown are net capacities which include a deduction for indoor fan
motor heat.
2. shows nominal (rated) capacities and power input.
3. TC and PI must be calculated by interpolation using the figures in the
above tables. (Figures out of the tables should not be used for
calculation.)
4. Capacities are based on the following conditions.
Corresponding refrigerant piping length : 25ft
Level difference : 0ft
EDB : Entering dry bulb temp. (°F)
TC : Total capacity (kBtu/h)
SHC : Sensible heating capacity (kBtu/h)
PI : Power input (kW)