Specifications

Installation Manual EDUS04-740
40 Room Air Conditioners D-Series
Indoor Unit Installation Drawings
Wrap the insulation pipe with
the finishing tape from bottom
to top.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe’s cut line.
Caulk
pipe hole
gap
with putty.
13/16 in or more from ceiling
Front panel
115/16 in or more from walls
(on both sides)
M3/16” × 1/2”L
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
A Mounting plate
Service lid
C
Air-purifying filter with photocatalytic
deodorizing function
Tabs (upper 3 locations)
Tabs (lower 3 locations)
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Lift the service lid upward.
Air filters
Insert the upper side of the Air-purifying filter
with photocatalytic deodorizin function into the tabs
(upper 3 locations),push the lower side of the filters
up a little and into the tabs (lower 3 locations).
C
Intelligent-eye sensor
Intelligent-eye sensor
1) Do not hit or violently push the Intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the
sensor’s detection area.
Caution
D Wireless
remote controller
F
(M1/8” X 13/16”L)
E
Remote
control holder
Before screwing the remote
control holder to the wall,
make sure that control
signals are properly
received by indoor unit.