Indoor Unit Installation
1. Installing the mounting plate.
The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark
the boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting-plate retention spots and Dimensions
4 15/16
2 3/8
3 1/8
19 13/16 1 3/4
11 7/16
2 1/16
41 5/16
3 15/16
2 1/16 3 9/16
3 15/16
3 15/16
Keep here the piece cut out
from the unit for piping
Through-the-wall
hole φ3 1/8
Drain hose position
φ
3 1/8
φ
3 1/8
Recommended mounting - plate retention
spots (9 spots in all)
(Bolt size : M3/8) (Bolt size : M3/8)
Place a leveler on raised tab.
b
Use tape
measure
as shown.
Position the
end of tape
measure at
Δ
Gas pipe end
Liquid pipe end
* The removed pipe port cover can be
kept in the mounting plate pocket.
Removed pipe
port cover
A
Mounting plate