Option List Si34-704
354 Appendix
4.2 Option Lists (Outdoor Unit)
RXQ5 ~ 18PY1
C : 3D056901
RXQ20 ~ 36PY1
C : 3D056901
RXQ38 ~ 54PY1
C : 3D056901
Note)
:
Order products
Optional accessories
RXQ5PY1
RXQ8PY1
RXQ10PY1
RXQ12PY1
RXQ14PY1
RXQ16PY1
RXQ18PY1
Cool/Heat Selector
KRC19-26A
Cool/Heat
Selector
Fixing box
KJB111A
Distributive
Piping
Refnet header
KHRP26M22H
(Max. 4 branch)
KHRP26M22H,
(Max. 4 branch)
KHRP26M33H
(Max. 8 branch)
KHRP26M22H, KHRP26M33H,
(Max. 4 branch) (Max. 8 branch)
KHRP26M72H
(Max. 8 branch)
Refnet joint KHRP26A22T
KHRP26A22T,
KHRP26A33T
KHRP26A22T, KHRP26A33T,
KHRP26A72T
Outdoor unit multi connection piping kit
—
Central drain pan kit
KWC26C160 KWC26C280
KWC26C450
Digital Pressure Gauge Kit
BHGP26A1(E)
Optional accessories
RXQ20PY1
RXQ22PY1
RXQ24PY1
RXQ26PY1
RXQ28PY1
RXQ30PY1
RXQ32PY1
RXQ34PY1
RXQ36PY1
Cool/Heat Selector
KRC19-26A
Cool/Heat
Selector
Fixing box
KJB111A
Distributive
Piping
Refnet header
KHRP26M22H
(Max. 4 branch),
KHRP26M33H
(Max. 8 branch),
KHRP26M72H
(Max. 8 branch)
KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H
(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)
Refnet joint
KHRP26A22T,
KHRP26A33T,
KHRP26A72T
KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T
Outdoor unit multi connection piping kit
BHFP22P100
Pipe size reducer
— KHRP26M73TP, KHRP26M73HP
Central drain pan kit
KWC26C280
KWC26C450
KWC26C280
KWC26C450
KWC26C450
×2
Digital Pressure Gauge Kit
BHGP26A1(E)
Optional accessories
RXQ38PY1
RXQ40PY1
RXQ42PY1
RXQ44PY1
RXQ46PY1
RXQ48PY1
RXQ50PY1
RXQ52PY1
RXQ54PY1
Cool/Heat Selector
KRC19-26A
Cool/Heat
Selector
Fixing box
KJB111A
Distributive
Piping
Refnet header
KHRP26M22H, KHRP26M33H, KHRP26M72H, KHRP26M73H
(Max. 4 branch) (Max. 8 branch) (Max. 8 branch) (Max. 8 branch)
Refnet joint KHRP26A22T, KHRP26A33T, KHRP26A72T, KHRP26A73T
Outdoor unit multi connection piping kit
BHFP22P151
Pipe size reducer
KHRP26M73TP, KHRP26M73HP
Central drain pan kit
KWC26C280
KWC26C450×2
KWC26C450×3
Digital Pressure Gauge Kit
BHGP26A1(E)